| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FN2030B-20-08LINE FILTER 250VAC/VDC 20A CHASS |
3,712 |
|
Datasheet | FN 2030 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 20 A | 50 ~ 60Hz | Medical | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 4mH |
|
FLLD3003AAW04LINE FILTER 3A CHASSIS MOUNT |
1,143 |
|
Datasheet | FLLD3 – AW | Bulk | Active | Three Phase (Wye) | Single Stage | - | - | 250 V | 440 V | 3 A | 50 ~ 60Hz | General Purpose | UL | -25°C ~ 85°C | Chassis Mount | Quick Connect | 450µH |
|
FLLD3006AAW04LINE FILTER 6A CHASSIS MOUNT |
1,580 |
|
Datasheet | FLLD3 – AW | Bulk | Last Time Buy | Three Phase (Wye) | Single Stage | - | - | 250 V | 440 V | 6 A | 50 ~ 60Hz | General Purpose | UL | -25°C ~ 85°C | Chassis Mount | Quick Connect | 450µH |
|
RSMN-2010DLINE FILTER 250VAC/VDC 10A DIN |
3,473 |
|
Datasheet | RSMN | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | DIN Rail | Terminal Block | - |
|
RSMN-2010LDLINE FILTER 250VAC/VDC 10A DIN |
3,626 |
|
Datasheet | RSMN | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | DIN Rail | Terminal Block | - |
|
NAC-20-102-DLINE FILTER 250VAC/VDC 20A DIN |
2,710 |
|
Datasheet | NAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
NAC-20-222-DLINE FILTER 250VAC/VDC 20A DIN |
1,672 |
|
Datasheet | NAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
NAC-20-332-DLINE FILTER 250VAC/VDC 20A DIN |
3,231 |
|
Datasheet | NAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
NAC-20-472-DLINE FILTER 250VAC/VDC 20A DIN |
2,139 |
|
Datasheet | NAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
NAC-20-681-DLINE FILTER 250VAC/VDC 20A DIN |
4,004 |
|
Datasheet | NAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
NAM-20-000-DLINE FILTER 250VAC/VDC 20A DIN |
4,603 |
|
Datasheet | NAM | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
NAM-20-101-DLINE FILTER 250VAC/VDC 20A DIN |
2,005 |
|
Datasheet | NAM | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
NAM-20-221-DLINE FILTER 250VAC/VDC 20A DIN |
3,215 |
|
Datasheet | NAM | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
NAM-20-331-DLINE FILTER 250VAC/VDC 20A DIN |
1,063 |
|
Datasheet | NAM | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
NAM-20-471-DLINE FILTER 250VAC/VDC 20A DIN |
2,668 |
|
Datasheet | NAM | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
6609036-4LINE FILTER 250VAC 3A CHASS MNT |
1,152 |
|
Datasheet | SK | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | - |
|
3-137-015LINE FILTER 125V/250VAC 12A CHAS |
4,756 |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 12 A | 50 ~ 60Hz | Medical | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
3-137-024LINE FILTER 125V/250VAC 12A CHAS |
3,324 |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 12 A | 50 ~ 60Hz | Medical | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
FLLE2006AUMDLINE FILTER 300VAC/VDC 6A CHASS |
1,351 |
|
Datasheet | FLLE2-U | Bulk | Last Time Buy | Single Phase | Two Stage | 300V | 300V | - | - | 6 A | 50/60Hz | Medical | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 8mH |
|
|
RSMN-2016LLINE FILTER 250VAC/VDC 16A CHASS |
3,785 |
|
Datasheet | RSMN | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 16 A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.