| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
EAM-16-331-DLINE FILTER 250VAC/VDC 16A DIN |
4,198 |
|
Datasheet | EAM | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAM-16-471-DLINE FILTER 250VAC/VDC 16A DIN |
1,677 |
|
Datasheet | EAM | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
ESC-16-332LINE FILTER 250VAC/VDC 16A CHASS |
2,793 |
|
Datasheet | ESC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
ESC-16-681LINE FILTER 250VAC/VDC 16A CHASS |
3,936 |
|
Datasheet | ESC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
ESM-16-471LINE FILTER 250VAC/VDC 16A CHASS |
2,298 |
|
Datasheet | ESM | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
RSAN-2020LDLINE FILTER 250VAC/VDC 20A DIN |
2,684 |
|
Datasheet | RSAN | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 20 A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | DIN Rail | Terminal Block | - |
|
FN2020A-20-08LINE FILTER 250VAC/VDC 20A CHASS |
1,528 |
|
Datasheet | FN 2020 | Bulk | Active | Single Phase | Single Stage | 250V | 250V | - | - | 20 A | DC ~ 400Hz | Safety | CE, CQC, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 600µH |
|
04DRPS4(D)LINE FILTER 250VAC 4A CHASS MNT |
2,586 |
|
Datasheet | DRP | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 4 A | 50/60Hz | General Purpose | cURus, ENEC | - | Chassis Mount | Terminal Block | 6.4mH |
|
|
20DRGG5LINE FILTER 115V/250VAC 20A CHAS |
3,346 |
|
Datasheet | DR | Box | Active | Single Phase | Two Stage | - | 115V, 250V | - | - | 20 A | 50/60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1mH |
|
FLLE2016APMBLINE FILTER 300VAC/VDC 16A CHASS |
3,973 |
|
Datasheet | FLLE2-P | Bulk | Last Time Buy | Single Phase | Single Stage | 300V | 300V | - | - | 16 A | 50/60Hz | Medical | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 800µH |
|
AMI-27A-12-3LINE FILTER 250VAC 12A CHASS MNT |
4,829 |
|
Datasheet | AMI-27 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 12 A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 6.5mH |
|
AMI-27B-12-3LINE FILTER 250VAC 12A CHASS MNT |
0 |
|
Datasheet | AMI-27 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 12 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 6.5mH |
|
AMI-26A-1-1LINE FILTER 250VAC 1A CHASS MNT |
4,643 |
|
Datasheet | AMI-26 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 24mH |
|
AG-030LINE FILTER 110V/250VAC 30A CHAS |
4,537 |
|
Datasheet | AG | Box | Obsolete | Single Phase | Single Stage | - | 110V, 250V | - | - | 30 A | 50/60Hz | General Purpose | cCSAus, CE, UR | -25°C ~ 85°C | Chassis Mount | Threaded Post (M5) | - |
|
EAC-16-102-DLINE FILTER 250VAC/VDC 16A DIN |
3,759 |
|
Datasheet | EAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAC-16-222-DLINE FILTER 250VAC/VDC 16A DIN |
4,182 |
|
Datasheet | EAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAC-16-332-DLINE FILTER 250VAC/VDC 16A DIN |
4,634 |
|
Datasheet | EAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAC-16-472-DLINE FILTER 250VAC/VDC 16A DIN |
1,625 |
|
Datasheet | EAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
EAC-16-681-DLINE FILTER 250VAC/VDC 16A DIN |
1,223 |
|
Datasheet | EAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
SNR-10-000-TLINE FILTER 50VDC 10A CHASS MNT |
4,242 |
|
Datasheet | SNR | Box | Active | DC | Single Stage | 50V | - | - | - | 10 A | - | General Purpose | cURus, TUV | -40°C ~ 71°C | Chassis Mount | Terminal Block | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.