Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Filter Type Configuration Voltage - Rated DC Voltage - Rated AC Voltage - Rated AC (Phase to Ground/Neutral) Voltage - Rated AC (Phase to Phase) Current Frequency - Operating Applications Approval Agency Operating Temperature Mounting Type Termination Style Inductance
FMAB-N4PK-2046 SCHURTER Inc.

FMAB-N4PK-2046

LINE FLTR 277/400VDC 277VAC CHAS

SCHURTER Inc.

2,488
Datasheet FMAB Box Active Single Phase Single Stage 277V, 400V 277V - - 20 A 50/60Hz General Purpose cURus, ENEC, VDE -40°C ~ 100°C Chassis Mount Quick Connect -
FMBB-3309-0640 SCHURTER Inc.

FMBB-3309-0640

LINE FILTER 125V/250VAC 6A CHASS

SCHURTER Inc.

3,835
Datasheet FMBB EP Box Active Single Phase Two Stage - 125V, 250V - - 6 A 50/60Hz Medical cURus, ENEC, VDE -40°C ~ 100°C Chassis Mount Quick Connect -
5500.2648.03 SCHURTER Inc.

5500.2648.03

LINE FILTER 125V/250VAC 60A CHAS

SCHURTER Inc.

1,451
Datasheet FMAB NEO Box Active Single Phase Single Stage - 125V, 250V - - 60 A 50/60Hz General Purpose cURus, ENEC, VDE -40°C ~ 100°C Chassis Mount Threaded Post (M6) -
5500.2658.09 SCHURTER Inc.

5500.2658.09

LINE FILTER 125V/250VAC 60A CHAS

SCHURTER Inc.

2,505
Datasheet FMAB NEO Box Active Single Phase Single Stage - 125V, 250V - - 60 A 50/60Hz Medical cURus, ENEC, VDE -40°C ~ 100°C Chassis Mount Threaded Post (M6) -
FMBD-345B-6412 SCHURTER Inc.

FMBD-345B-6412

LINE FILTER 520VAC 64A CHASS MNT

SCHURTER Inc.

3,750
Datasheet FMBD EP Box Active Three Phase (Wye) Two Stage - 520V - - 64 A 50/60Hz General Purpose cURus, ENEC, UL, VDE -40°C ~ 100°C Chassis Mount Terminal Block -
5500.2070 SCHURTER Inc.

5500.2070

LINE FILTER 125V/250VAC 16A CHAS

SCHURTER Inc.

1,948
Datasheet FMBB Bulk Active Single Phase Two Stage - 125V, 250V - - 16 A 50/60Hz Inverters, Power Drive Systems cURus, ENEC, VDE -25°C ~ 100°C Chassis Mount Terminal Block 3.5mH
FMBD-395D-J812 SCHURTER Inc.

FMBD-395D-J812

LINE FLTR 520VAC 180A CHASS MNT

SCHURTER Inc.

4,753
Datasheet FMBD EP Box Active Three Phase (Wye) Two Stage - 520V - - 180 A 50/60Hz General Purpose cURus, ENEC, UL, VDE -40°C ~ 100°C Chassis Mount Terminal Block -
5500.2643.01 SCHURTER Inc.

5500.2643.01

LINE FILTER 125V/250VAC 10A CHAS

SCHURTER Inc.

4,304
Datasheet FMAB NEO Box Active Single Phase Single Stage - 125V, 250V - - 10 A 50/60Hz General Purpose cURus, ENEC, VDE -40°C ~ 100°C Chassis Mount Quick Connect -
FPBB-U3RI-1090.VD SCHURTER Inc.

FPBB-U3RI-1090.VD

LINE FILTER 250VAC/VDC 10A DIN

SCHURTER Inc.

4,465
Datasheet FPBB RAIL Box Active Single Phase Two Stage 250V 250V - - 10 A 50/60Hz General Purpose cURus, ENEC, UL, VDE -40°C ~ 100°C DIN Rail Spring Cage -
FPBB-U3RI-0690.VD SCHURTER Inc.

FPBB-U3RI-0690.VD

LINE FILTER 250VAC/VDC 6A DIN

SCHURTER Inc.

2,667
Datasheet FPBB RAIL Box Active Single Phase Two Stage 250V 250V - - 6 A 50/60Hz General Purpose cURus, ENEC, UL, VDE -40°C ~ 100°C DIN Rail Spring Cage -
Total 933 Record«Prev1... 3637383940414243...94Next»
FAQ

Frequently Asked Questions

What are Power Line Filter Modules components used for?

Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Power Line Filter Modules part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

PART MATCHING & SOURCING

Need Help Narrowing Down the Right Power Line Filter Modules Part?

Send your target specifications, preferred manufacturer, quantity or reference part number. Our team can help check matching options, availability and quotation details for your sourcing requirement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top