ICMENU Electronics — Your one-stop global supplier of chips and electronic components.
FILTERED COMPONENT SELECTION

Power Line Filter Modules

Review Power Line Filter Modules Filters components in this filtered selection. Compare manufacturer information, availability, pricing, datasheets and key specifications to narrow down suitable parts for your application.

If the exact part or specification you need is not listed, send the manufacturer part number, target parameters and quantity to ICMENU for sourcing and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Filter Type Configuration Voltage - Rated DC Voltage - Rated AC Voltage - Rated AC (Phase to Ground/Neutral) Voltage - Rated AC (Phase to Phase) Current Frequency - Operating Applications Approval Agency Operating Temperature Mounting Type Termination Style Inductance
FPBB-U3TI-0690 SCHURTER Inc.

FPBB-U3TI-0690

LINE FILTER 250VAC/VDC 6A CHASS

SCHURTER Inc.

2,597
Datasheet FPBB RAIL Box Active Single Phase Two Stage 250V 250V - - 6 A 50/60Hz General Purpose cURus, ENEC, UL, VDE -40°C ~ 100°C Chassis Mount Spring Cage -
FPBB-U3TI-0390 SCHURTER Inc.

FPBB-U3TI-0390

LINE FILTER 250VAC/VDC 3A CHASS

SCHURTER Inc.

3,363
Datasheet FPBB RAIL Box Active Single Phase Two Stage 250V 250V - - 3 A 50/60Hz General Purpose - -40°C ~ 100°C Chassis Mount Spring Cage -
3-134-827 SCHURTER Inc.

3-134-827

LINE FILTER 250VAC 12A CHASS MNT

SCHURTER Inc.

3,406
Datasheet FMAB NEO Box Active Single Phase Single Stage - 250V - - 12 A - Medical cURus, ENEC, VDE -40°C ~ 100°C Chassis Mount Quick Connect -
FMAD-33SZ-1042.SP SCHURTER Inc.

FMAD-33SZ-1042.SP

LINE FILTER 300V/520VAC 10A CHAS

SCHURTER Inc.

2,384
Datasheet FMAD CP Bulk Active Three Phase (Wye) Single Stage - 300V, 520V - - 10 A 50/60Hz Photovoltaic Inverter cURus, ENEC, VDE -40°C ~ 100°C Chassis Mount Terminal Block -
5500.2043 SCHURTER Inc.

5500.2043

LINE FILTER 125V/250VAC 2A CHASS

SCHURTER Inc.

2,198
Datasheet FMW-52 Bulk Active Single Phase Two Stage - 125V, 250V - - 2 A 50/60Hz General Purpose cURus, ENEC, VDE -25°C ~ 100°C Chassis Mount Quick Connect 3mH
FMAD-34SZ-1042.SP SCHURTER Inc.

FMAD-34SZ-1042.SP

LINE FILTER 300V/520VAC 10A CHAS

SCHURTER Inc.

4,628
Datasheet FMAD CP Bulk Active Three Phase (Wye) Single Stage - 300V, 520V - - 10 A 50/60Hz Photovoltaic Inverter cURus, ENEC, VDE -40°C ~ 100°C Chassis Mount Terminal Block -
FMAD-34SZ-0342.SP SCHURTER Inc.

FMAD-34SZ-0342.SP

LINE FILTER 300V/520VAC 3A CHASS

SCHURTER Inc.

4,740
Datasheet FMAD CP Bulk Active Three Phase (Wye) Single Stage - 300V, 520V - - 3 A 50/60Hz Photovoltaic Inverter cURus, ENEC, VDE -40°C ~ 100°C Chassis Mount Terminal Block -
5500.2074 SCHURTER Inc.

5500.2074

LINE FILTER 125V/250VAC 16A CHAS

SCHURTER Inc.

4,819
Datasheet FMLB-09 Bulk Active Single Phase Single Stage - 125V, 250V - - 16 A 50/60Hz Medical cURus, ENEC, VDE -25°C ~ 100°C Chassis Mount Quick Connect 640µH
FMAD-33SZ-2042.HP SCHURTER Inc.

FMAD-33SZ-2042.HP

LINE FILTER 300V/520VAC 20A CHAS

SCHURTER Inc.

3,343
Datasheet FMAD CP Bulk Active Three Phase (Wye) Single Stage - 300V, 520V - - 20 A 50/60Hz Photovoltaic Inverter cURus, ENEC, VDE -40°C ~ 100°C Chassis Mount Terminal Block -
5500.2037 SCHURTER Inc.

5500.2037

LINE FILTER 125V/250VAC 16A CHAS

SCHURTER Inc.

3,039
Datasheet FMLB-51 Bulk Active Single Phase Single Stage - 125V, 250V - - 16 A 50/60Hz Inverters, Power Drive Systems cURus, ENEC, VDE -25°C ~ 100°C Chassis Mount Quick Connect 2mH
Total 933 Record«Prev1... 1415161718192021...94Next»
FAQ

Frequently Asked Questions

What are Power Line Filter Modules components used for?

Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Power Line Filter Modules part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

PART MATCHING & SOURCING

Need Help Narrowing Down the Right Power Line Filter Modules Part?

Send your target specifications, preferred manufacturer, quantity or reference part number. Our team can help check matching options, availability and quotation details for your sourcing requirement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top