Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
5500.2636.01LINE FILTER 125V/250VAC 12A CHAS |
214 |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 12 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
|
6609020-1LINE FILTER 250VAC 1A CHASS MNT |
102 |
|
Datasheet | B | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 1 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.86mH |
|
|
10EB1LINE FILTER 250VAC 10A CHASS MNT |
177 |
|
Datasheet | B | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 495µH |
|
|
6609020-7LINE FILTER 250VAC 5A CHASS MNT |
108 |
|
Datasheet | B | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 5 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 516µH |
|
5500.2644.07LINE FILTER 125V/250VAC 12A CHAS |
108 |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 12 A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
PLF-27D1-3A-WLINE FILTER 115V/250VAC 3A CHASS |
197 |
|
Datasheet | PLF | Tray | Active | Single Phase | Two Stage | - | 115V, 250V | - | - | 3 A | 50 ~ 60Hz | - | cURus | -25°C ~ 85°C | Chassis Mount | Wire Leads | L1 - 420µH, L2 - 70µH |
|
PLF-22D1-6A-WLINE FILTER 115V/250VAC 6A CHASS |
118 |
|
Datasheet | PLF | Tray | Active | Single Phase | Two Stage | - | 115V, 250V | - | - | 6 A | 50 ~ 60Hz | - | cURus | -25°C ~ 85°C | Chassis Mount | Wire Leads | 1.5mH |
|
6609020-6LINE FILTER 250VAC 3A CHASS MNT |
162 |
|
Datasheet | B | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 1.76mH |
|
PLF-21D3-10A-QLINE FILTER 115V/250VAC 10A CHAS |
149 |
|
Datasheet | PLF | Tray | Active | Single Phase | Two Stage | - | 115V, 250V | - | - | 10 A | 50 ~ 60Hz | - | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | 600µH |
|
5500.0255.1LINE FILTER 125V/250VAC 2A TH |
231 |
|
Datasheet | 5500 | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 2 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 85°C | Through Hole | PC Pins | 4mH |
|
5500.0455.1LINE FILTER 125V/250VAC 4A TH |
152 |
|
Datasheet | 5500 | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 4 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 85°C | Through Hole | PC Pins | 1.6mH |
|
5500.0655.3LINE FILTER 125V/250VAC 6A TH |
189 |
|
Datasheet | 5500 | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 6 A | 50/60Hz | Medical | cURus, ENEC, VDE | -25°C ~ 85°C | Through Hole | PC Pins | 700µH |
|
|
6609028-6LINE FILTER 250VAC 3A CHASS MNT |
138 |
|
Datasheet | K | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 3 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 1.76mH |
|
FN420-2.5-13LINE FLTR 250VAC 2.5A CHASS MNT |
124 |
|
Datasheet | FN 420 | Tray | Not For New Designs | Single Phase | Single Stage | - | 250V | - | - | 2.5 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | - | Chassis Mount | Quick Connect | 3.4mH |
|
FN420-4-13LINE FILTER 250VAC 4A CHASS MNT |
199 |
|
Datasheet | FN 420 | Tray | Not For New Designs | Single Phase | Single Stage | - | 250V | - | - | 4 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | - | Chassis Mount | Quick Connect | 2mH |
|
FN422-2.5-13LINE FLTR 250VAC 2.5A CHASS MNT |
199 |
|
Datasheet | FN 422 | Tray | Not For New Designs | Single Phase | Single Stage | - | 250V | - | - | 2.5 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | - | Chassis Mount | Quick Connect | 3.4mH |
|
FN422-4-13LINE FILTER 250VAC 4A CHASS MNT |
200 |
|
Datasheet | FN 422 | Tray | Not For New Designs | Single Phase | Single Stage | - | 250V | - | - | 4 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | - | Chassis Mount | Quick Connect | 2mH |
|
FN420-6.5-13LINE FLTR 250VAC 6.5A CHASS MNT |
165 |
|
Datasheet | FN 420 | Tray | Not For New Designs | Single Phase | Single Stage | - | 250V | - | - | 6.5 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | - | Chassis Mount | Quick Connect | 750µH |
|
FN422-6.5-13LINE FLTR 250VAC 6.5A CHASS MNT |
190 |
|
Datasheet | FN 422 | Tray | Not For New Designs | Single Phase | Single Stage | - | 250V | - | - | 6.5 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | - | Chassis Mount | Quick Connect | 750µH |
|
|
FN2010A-16-06LINE FILTER 250VAC 16A CHASS MNT |
129 |
|
Datasheet | FN 2010 | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 700µH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.