| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
5500.2261LINE FILTER 125V/250VAC 10A CHAS |
4,406 |
|
Datasheet | FMAB RAIL | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 10 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1mH |
|
FMAC-3RYB-1010LINE FILTER 480VAC 10A DIN RAIL |
4,119 |
|
Datasheet | FMAC RAIL | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | 10 A | - | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
TFI 150LINE FILTER 43V/160VDC TH |
2,379 |
|
Datasheet | TFI (150W) | Tube | Active | DC | Two Stage | 43V, 160V | - | - | - | - | - | General Purpose | - | -40°C ~ 95°C | Through Hole | PC Pins | - |
|
|
F2700AA06LINE FILTER 250VAC 6A CHASS MNT |
2,241 |
|
Datasheet | F2700 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | CE, CSA, TUV, UR | - | Chassis Mount | Quick Connect | - |
|
5500.2055LINE FILTER 125V/250VAC 6A CHASS |
2,536 |
|
Datasheet | FSS | Bulk | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 6 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
TFI 300LINE FILTER 43V/160VDC TH |
1,570 |
|
Datasheet | TFI (300W) | Tube | Active | DC | Two Stage | 43V, 160V | - | - | - | - | - | General Purpose | - | -40°C ~ 95°C | Through Hole | PC Pins | - |
|
FN2020A-30-08LINE FILTER 250VAC 30A CHASS MNT |
4,546 |
|
Datasheet | FN 2020 | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 30 A | DC ~ 400Hz | Safety | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 670µH |
|
FMBB-34ME-2040LINE FILTER 125V/250VAC 20A CHAS |
2,123 |
|
Datasheet | FMBB EP | Box | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 20 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
FN343-6-05LINE FILTER 250VAC 6A CHASS MNT |
3,975 |
|
Datasheet | FN 343 | Tray | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 430µH |
|
B84113H0000M125LINE FILTER 250VAC/VDC 25A CHASS |
4,509 |
|
Datasheet | B84113 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 25 A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M5) | 800µH |
|
|
FN2410-8-44LINE FILTER 250VAC 8A CHASS MNT |
1,618 |
|
Datasheet | FN 2410 | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 8 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
B84113H0000G136LINE FILTER 250VAC/VDC 36A CHASS |
1,567 |
|
Datasheet | B84113 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 36 A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M5) | 500µH |
|
FMBB-34MF-3030LINE FILTER 125V/250VAC 30A CHAS |
1,978 |
|
Datasheet | FMBB EP | Box | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 30 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Threaded Post (M4) | - |
|
B84115E0000B110LINE FILTER 250VAC/VDC 10A CHASS |
4,191 |
|
Datasheet | B84115E | Box | Active | Single Phase | Two Stage | 250V | 250V | - | - | 10 A | 50 ~ 60Hz | Medical | CSA, ENEC, UL | - | Chassis Mount | Quick Connect | - |
|
FMBB-33MF-3030LINE FILTER 125V/250VAC 30A CHAS |
2,023 |
|
Datasheet | FMBB EP | Box | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 30 A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Threaded Post (M4) | - |
|
5500.2625.01LINE FILTER 125V/250VAC 16A CHAS |
4,540 |
|
Datasheet | FMBB NEO | Bulk | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 16 A | - | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2.8mH |
|
FN2080-12-08LINE FILTER 250VAC/VDC 12A CHASS |
4,127 |
|
Datasheet | FN 2080 | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 12 A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 3.2mH |
|
NBH-30-202LINE FILTER 250VAC/VDC 30A CHASS |
2,926 |
|
Datasheet | NBH | Box | Active | Single Phase | Two Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMBB-36MF-3030LINE FILTER 125V/250VAC 30A CHAS |
1,249 |
|
Datasheet | FMBB EP | Box | Active | Single Phase | Two Stage | - | 125V, 250V | - | - | 30 A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Threaded Post (M4) | - |
|
6EHQ3LINE FILTER 250VAC 6A CHASS MNT |
3,633 |
|
Datasheet | HQ | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 6 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 48.8mH |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.