Power Line Filter Modules
Explore Power Line Filter Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AMI-23B-16-1LINE FILTER 250VAC 16A CHASS MNT |
2,151 |
|
Datasheet | AMI-23 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | - | 4mH |
|
AMI-27B-1-1LINE FILTER 250VAC 1A CHASS MNT |
2,783 |
|
Datasheet | AMI-27 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
ES1-T10LINE FILTER 250VAC/VDC 10A CHASS |
1,229 |
|
Datasheet | ES1 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | 50 ~ 60Hz | General Purpose | CQC, CSA, TUV, UR | -25°C ~ 85°C | Chassis Mount | Threaded Post (M4) | - |
|
AMI-27-1-1LINE FILTER 250VAC 1A CHASS MNT |
1,905 |
|
Datasheet | AMI-27 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
AMI-23-16-1LINE FILTER 250VAC 16A CHASS MNT |
4,325 |
|
Datasheet | AMI-23 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | - | 4mH |
|
AMI-22-16-3LINE FILTER 250VAC 16A CHASS MNT |
2,126 |
|
Datasheet | AMI-22 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 16 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | - | 650µH |
|
AMI-M12AA-1-10-BLINE FILTER 250VAC 10A CHASS MNT |
2,117 |
|
Datasheet | AMI-M12AA | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.2mH |
|
AMI-26-12-1LINE FILTER 250VAC 12A CHASS MNT |
1,235 |
|
Datasheet | AMI-26 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 12 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.16mH |
|
AMI-22B-20-1LINE FILTER 250VAC 20A CHASS MNT |
4,113 |
|
Datasheet | AMI-22 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 20 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 600µH |
|
EAC-16-332LINE FILTER 250VAC/VDC 16A CHASS |
2,183 |
|
Datasheet | EAC | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 16 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
AMI-28-1-1LINE FILTER 250VAC 1A CHASS MNT |
1,421 |
|
Datasheet | AMI-28 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 22.4mH |
|
AMI-22-20-1LINE FILTER 250VAC 20A CHASS MNT |
4,792 |
|
Datasheet | AMI-22 | Box | Active | Single Phase | Single Stage | - | 250V | - | - | 20 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 600µH |
|
EAP-06-471LINE FILTER 250VAC/VDC 6A CHASS |
2,850 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 6 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
EAP-06-101LINE FILTER 250VAC/VDC 6A CHASS |
4,561 |
|
Datasheet | EAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 6 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
RCS7A-6VLINE FILTER 150VAC SURFACE MOUNT |
3,853 |
|
Datasheet | - | Bulk | Active | Single Phase | - | - | 150V | - | - | - | 50 ~ 60Hz | General Purpose | cURus | -40°C ~ 85°C | Surface Mount | Wire Leads | - |
|
ES1-T15LINE FILTER 250VAC/VDC 15A CHASS |
3,706 |
|
Datasheet | ES1 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 15 A | 50 ~ 60Hz | General Purpose | CQC, CSA, TUV, UR | -25°C ~ 85°C | Chassis Mount | Threaded Post (M4) | - |
|
AMI-29B-4-1LINE FILTER 250VAC 4A CHASS MNT |
1,219 |
|
Datasheet | AMI-29 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 4 A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 28mH |
|
AMI-29-4-1LINE FILTER 250VAC 4A CHASS MNT |
0 |
|
Datasheet | AMI-29 | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 4 A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 28mH |
|
TBA-10H443ALINE FILTER 250VAC/VDC 10A CHASS |
2,584 |
|
Datasheet | TBA | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 10 A | 50 ~ 60Hz | General Purpose | CE, CQC, CSA, ENEC, SEMKO | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
ES1-T20LINE FILTER 250VAC/VDC 20A CHASS |
4,205 |
|
Datasheet | ES1 | Box | Active | Single Phase | Single Stage | 250V | 250V | - | - | 20 A | 50 ~ 60Hz | General Purpose | CQC, CSA, TUV, UR | -25°C ~ 85°C | Chassis Mount | Threaded Post (M4) | - |
Frequently Asked Questions
What are Power Line Filter Modules components used for?
Power Line Filter Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Line Filter Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Line Filter Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.