Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Mounting Type Current - Max Region Utilized Overload Protection Connector - AC Input AC Outlets Connector - AC Output Voltage - Input Housing Material Media Lines Protected Energy Cord Length Approval Agency Features
PDUB20 Tripp Lite

PDUB20

PDU HOT SWAP 100-127V 16A

Tripp Lite

3,412
Datasheet - Bulk Obsolete PDU (Power Distribution Unit) Rack, Horizontal 16A North America - NEMA 5-20P (2) 8 NEMA 5-15R (2), 5-20R (2) 120V Steel - - 6' (1.83m) CSA, UL -
PDUB30 Tripp Lite

PDUB30

PDU DUAL HOT SWAP 120V 30A

Tripp Lite

2,526
Datasheet - Bulk Obsolete PDU (Power Distribution Unit) Rack, Horizontal 24A North America - NEMA L5-30P (2) 7 NEMA 5-20R (6), NEMA L5-30R 120V Steel - - 6' (1.83m) CSA, UL -
PDUBHV10 Tripp Lite

PDUBHV10

PDU DUAL SOURCE W/ HOT SWAP

Tripp Lite

1,398
Datasheet - Bulk Obsolete PDU (Power Distribution Unit) Rack, Horizontal 10A International - IEC 320-C14 (2) 8 IEC 320-C13 200 ~ 240V Steel - - 6' (1.83m) CE, CSA, UL -
PDUMH15NET2 Tripp Lite

PDUMH15NET2

PDU SWITCHED 120V 15A 8 OUTLET

Tripp Lite

2,410
Datasheet - Bulk Obsolete PDU (Power Distribution Unit) Rack, Horizontal 15A International - NEMA 5-15P 8 NEMA 5-15R 100 ~ 127V Steel - - 12' (3.66m) CSA, NOM, UL Load Meter
PDUMH20NET2 Tripp Lite

PDUMH20NET2

PDU SWITCHED 5-15/20R 8 OUTLET

Tripp Lite

2,859
Datasheet - Bulk Obsolete PDU (Power Distribution Unit) Rack, Horizontal 20A North America - NEMA L5-20P 8 NEMA 5-20R 120V Steel - - 12' (3.66m) CSA, NOM, UL Load Meter
PDUMNV15 Tripp Lite

PDUMNV15

PDU MONITORED 15A 5-15R 16 OUT

Tripp Lite

2,063
Datasheet - Bulk Obsolete PDU (Power Distribution Unit) Rack, Vertical 15A North America - NEMA 5-15P 16 NEMA 5-15R 120V Metal - - 10' (3.05m) NOM, UL Load Meter
PDUMNV20 Tripp Lite

PDUMNV20

PDU MONITORED 5-15/20R 24 OUTLET

Tripp Lite

4,741
Datasheet - Bulk Obsolete PDU (Power Distribution Unit) Rack, Vertical 20A North America - NEMA L5-20P 24 NEMA 5-20R 120V Metal - - 10' (3.05m) NOM, UL Load Meter
PDUMNV20HV Tripp Lite

PDUMNV20HV

PDU MONITORED 208V-240V 20A C13

Tripp Lite

4,514
Datasheet - Bulk Obsolete PDU (Power Distribution Unit) Rack, Vertical 20A North America - NEMA L6-20P 24 IEC 320-C13 (20), C19 (4) 200 ~ 240V Metal - - 10' (3.05m) CE, NOM, UL Load Meter
PDUMNV20HV2 Tripp Lite

PDUMNV20HV2

PDU MONITORED 200V-240V 20A C13

Tripp Lite

3,350
Datasheet - Bulk Obsolete PDU (Power Distribution Unit) Rack, Vertical 20A North America - NEMA L6-20P 20 IEC 320-C13 (18), C19 (2) 200 ~ 240V Metal - - 10' (3.05m) CE, NOM, UL Load Meter
PDUMNV30 Tripp Lite

PDUMNV30

PDU MONITORED 5-15/20R 24 OUTLET

Tripp Lite

2,208
Datasheet - Bulk Obsolete PDU (Power Distribution Unit) Rack, Vertical 30A North America Circuit Breaker(s) NEMA L5-30P 24 NEMA 5-20R 120V Metal - - 10' (3.05m) NOM, UL Load Meter
Total 1655 Record«Prev1... 155156157158159160161162...166Next»
FAQ

Frequently Asked Questions

What are Power Distribution, Surge Protectors components used for?

Power Distribution, Surge Protectors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Power Distribution, Surge Protectors part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Power Distribution, Surge Protectors parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

PART MATCHING & SOURCING

Need Help Narrowing Down the Right Power Distribution, Surge Protectors Part?

Send your target specifications, preferred manufacturer, quantity or reference part number. Our team can help check matching options, availability and quotation details for your sourcing requirement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top