Power Distribution, Surge Protectors
Explore Power Distribution, Surge Protectors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Mounting Type | Current - Max | Region Utilized | Overload Protection | Connector - AC Input | AC Outlets | Connector - AC Output | Voltage - Input | Housing Material | Media Lines Protected | Energy | Cord Length | Approval Agency | Features |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
1583H6A1SBKSURGE SUPPRESSR 6OUT 6' CORD |
1,458 |
|
Datasheet | 1583 | Bag | Active | PDU, Surge Protector | Rack, Horizontal | 15A | North America | Circuit Breaker(s) | NEMA 5-15P | 6 | NEMA 5-15R | 120V | Steel | - | 780J | 6' (1.83m) | CSA, UL | - |
|
IBAR6ULTRAUSBBISOBAR 6-OUTLET SURGE PROTECTOR |
3,285 |
|
Datasheet | - | Bulk | Active | Outlet Strip, Power Strip, Surge Protector | Bench, Floor, Wall | 12A | North America | Circuit Breaker(s) | NEMA 5-15P | 6 | NEMA 5-15R | 120V | Metal | - | 3840J | 10' (3.05m) | CSA, cUL, UL | Switch, USB Charge Port(s) |
|
PS-606-HGDGSAFE-IT UL 2930 MEDICAL-GRADE PO |
2,216 |
|
Datasheet | Safe-IT™ | Box | Active | PDU (Power Distribution Unit) | Bench, Floor, Wall | 15A | International | Circuit Breaker(s) | NEMA 5-15P-HG | 6 | NEMA 5-15R-HG (6) | 120V | Metal | - | - | 6' (1.83m) | UL | - |
|
1589H48D116POWER STRIP 48" 20A 16OUT 15' |
1,247 |
|
Datasheet | 1589 | Bag | Active | PDU (Power Distribution Unit) | Bench, Rack, Wall | 20A | North America | Circuit Breaker(s) | NEMA L5-20P | 16 | NEMA 5-20R | 120V | Aluminum | - | - | 15' (4.57m) | CSA, UL | - |
|
PDUMH15-RAPDU SWITCHED 120V 15A 8 OUTLET |
2,275 |
|
Datasheet | - | Bulk | Active | PDU (Power Distribution Unit) | Rack, Horizontal | 15A | North America | Circuit Breaker(s) | NEMA 5-15P | 13 | NEMA 5-15R | 120V | Metal | - | - | 15' (4.57m) | CSA, cUL, UL | Load Meter |
|
|
8951480000SURGE PROTECTION |
3,260 |
|
Datasheet | - | Bulk | Active | - | DIN Rail | - | International | None | - | None | - | - | - | - | - | - | - | - |
|
P12B01MTHE 15A, 120V HORIZONTAL SINGLE |
2,857 |
|
Datasheet | - | Bulk | Active | PDU (Power Distribution Unit) | Rack, Horizontal | 15A | North America | - | NEMA 5-15P | 12 | NEMA 5-20R | 100 ~ 120V | - | - | - | 10' (3.05m) | UL | - |
|
BB-422HESPSURGE PROTECTOR HI ENERGY RS-422 |
3,768 |
|
Datasheet | - | Bulk | Active | Surge Protector for Media Lines Only | Chassis Mount | - | International | - | - | - | - | - | - | RS-422, RS-485 | - | - | CE, IEEE | - |
|
2801593SURGE SUPPRESSOR |
2,158 |
|
Datasheet | DT | Bulk | Active | Surge Protector for Media Lines Only | DIN Rail | 380mA | International | None | Screw Terminals | None | Screw Terminals | - | - | RJ45 | - | - | EAC | Ground |
|
|
2804623TVS DIODE 36VWM MODULE |
1,446 |
|
Datasheet | - | Bulk | Active | PDU (Power Distribution Unit) | DIN Rail | 350mA | International | Fuse Holder | Hardwired | - | Hardwired | 36V | Plastic | - | - | - | CCC, EAC, UL | - |
|
PDU1415POWER STRIP 14OUT 15'CORD 24" |
4,756 |
|
Datasheet | - | Bulk | Active | PDU (Power Distribution Unit) | Rack, Vertical | 15A | North America | Circuit Breaker(s) | NEMA 5-15P | 14 | NEMA 5-15R | 120V | Steel | - | - | 15' (4.57m) | CSA, UL | - |
|
2800768SURGE PROTECTION DEVICE |
4,008 |
|
Datasheet | - | Bulk | Active | - | DIN Rail | - | International | None | Screw Terminals | None | Screw Terminals | - | - | - | - | - | UL | - |
|
PDUH20-ISO61.92KW 120V SINGLE-PHASE BASIC P |
2,254 |
|
Datasheet | - | Bulk | Active | PDU (Power Distribution Unit) | Rack, Horizontal | 20A | North America | Circuit Breaker(s) | NEMA 5-20P, NEMA L5-20P | 14 | NEMA 5-15R (2), NEMA 5-15/20R (12) | 100 ~ 127V | Metal | - | 3840J | 6' (1.83m) | CSA, UL | - |
|
P12B47MBASIC PDU, 30AMP, (12)C13, NEMA |
4,565 |
|
Datasheet | SmartZone™ | Bulk | Active | PDU (Power Distribution Unit) | Rack, Horizontal | 30A | North America | None | NEMA L6-30P | 24 | C13 | 208V | - | - | - | 9.8' (3.00m) | UL | - |
|
|
SD32T3SURGE PROTECTION |
2,390 |
|
Datasheet | - | Bulk | Active | - | DIN Rail | - | International | None | - | None | - | - | - | - | - | - | - | - |
|
PDUMH15ATS1.44KW 120V SINGLE-PHASE ATS/MET |
4,039 |
|
Datasheet | - | Bulk | Active | PDU (Power Distribution Unit) | Rack, Wall | 15A | North America | None | NEMA 5-15P (2) | 8 | NEMA 5-15R | 120V | Metal | - | - | 12' (3.66m) | CSA, UL | Dual Power Input for Redundant Power Supplies, Dual Load Meters |
|
PDUMH15ATPOWER STRIP 8OUT RACK AMMETER |
2,574 |
|
Datasheet | - | Bulk | Active | PDU (Power Distribution Unit) | Rack, Horizontal | 15A | North America | None | NEMA 5-15P (2) | 8 | NEMA 5-15R | 120V | Steel | - | - | 12' (3.66m) | CSA, NOM, UL | Auto Transfer Switch, Load Meter |
|
PDUMNH32HVAT7.4KW SINGLE-PHASE 230V ATS/MONI |
4,010 |
|
Datasheet | - | Bulk | Active | PDU (Power Distribution Unit) | Rack, Horizontal | 32A | - | None | IEC 309 (2) | 1 | IEC 309 | 230V | Metal | - | - | 10' (3.05m) | CE | Auto Transfer Switch, Load Meter |
|
P24B14MBASIC PDU, 60AMP, (12)C13(12)C19 |
1,109 |
|
Datasheet | SmartZone™ | Bulk | Active | PDU (Power Distribution Unit) | Rack, Vertical | 60A | International | None | IEC 60309 3P | 24 | C13 (12), C19 (12) | 208V | - | - | - | 9.8' (3.00m) | UL | - |
|
|
4741.00004741 TWINBLOC INLET 2 OUT |
1,915 |
|
Datasheet | 4741 | Bulk | Active | Outlet Strip, Power Strip | Bench, Floor, Wall | 10A | International | None | IEC 320-C14 | 2 | IEC 320-C13 | 100 ~ 250V | Plastic | - | - | Without Cord | CSA, IEC, UL | - |
Frequently Asked Questions
What are Power Distribution, Surge Protectors components used for?
Power Distribution, Surge Protectors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Distribution, Surge Protectors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Power Distribution, Surge Protectors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.