Valves and Control
Explore Valves and Control parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Function | Actuator Type | Operating Pressure | Orifice Diameter | Fluid Type | Connection Method | For Use With/Related Products | Mounting Type | Features |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
VOVK-BT6-M32C-MN-5T1P-B3FSOLENOID VALVE |
2,191 |
|
Datasheet | VOVK | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | -14.5 ~ 102 PSI (-1 ~ 7 bar) | - | Air | Barbed Connection for Tubing 3.00mm Dia | Solenoid Valve | Chassis Mount | Supply Voltage 12VDC |
|
VOVK-BT6-M32C-MN-1T1P-B3.2FSOLENOID VALVE |
3,910 |
|
Datasheet | VOVK | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | -14.5 ~ 102 PSI (-1 ~ 7 bar) | - | Air | Barbed Connection for Tubing 3.20mm Dia | Solenoid Valve | Chassis Mount | Supply Voltage 24VDC |
|
VOVK-BT6-M32C-MN-5T1P-B3.2FSOLENOID VALVE |
3,978 |
|
Datasheet | VOVK | Bulk | Active | Solenoid Valve | 3/2 Normally Closed | - | -14.5 ~ 102 PSI (-1 ~ 7 bar) | - | Air | Barbed Connection for Tubing 3.20mm Dia | Solenoid Valve | Chassis Mount | Supply Voltage 12VDC |
|
VFOE-LE-T-G12-Q12-P20ONE-WAY FLOW CONTROL VALVE |
3,163 |
|
Datasheet | VFOE | Bulk | Active | Flow Restrictor, Adjustable | One-Way | - | 3 ~ 145 PSI (0.2 ~ 10 bar) | - | Air | Threaded M5 | Control Valve | Free Hanging (In-Line) | - |
|
GRE-3/8EXHAUST AIR FLOW CONTROL VALVE |
2,879 |
|
Datasheet | GRE | Bulk | Active | Control Valve | - | - | 0 ~ 145 PSI (0 ~ 10 bar) | - | Air | Threaded G3/8" | Control Valve | Free Hanging (In-Line) | - |
|
GRE-3/8-NPTEXHAUST AIR FLOW CONTROL VALVE |
3,906 |
|
Datasheet | GRE | Bulk | Active | Control Valve | - | - | 0 ~ 145 PSI (0 ~ 10 bar) | - | Air | Threaded 3/8" NPT | Control Valve | Free Hanging (In-Line) | - |
|
GRLO-M5-PK-3-BTHROTTLE VALVE |
1,892 |
|
Datasheet | GRLO | Bulk | Active | Flow Restrictor, Adjustable | - | - | 0 ~ 145 PSI (0 ~ 10 bar) | - | Air | Threaded M5 | Control Valve | Free Hanging (In-Line) | - |
|
VABS-S1-1S-N38SUB-BASE |
4,745 |
|
Datasheet | - | Bulk | Active | Sub-Base | - | - | 0 ~ 232 PSI (0 ~ 16 bar) | - | Air | Threaded 3/8" NPT | Control Valve | Chassis Mount | - |
|
VABS-S1-1S-G38SUB-BASE |
1,051 |
|
Datasheet | - | Bulk | Active | Sub-Base | - | - | 0 ~ 232 PSI (0 ~ 16 bar) | - | Air | Threaded G3/8" | Control Valve | Chassis Mount | - |
|
HA-1/8-QS-6CHECK VALVE |
2,019 |
|
Datasheet | HA | Bulk | Active | Non-Return Valve (Check Valve) | - | - | 14.5 ~ 145 PSI (1 ~ 10 bar) | - | Air | Threaded | Control Valve | Free Hanging (In-Line) | - |
|
HB-1/8-QS-6CHECK VALVE |
1,943 |
|
Datasheet | HB | Bulk | Active | Non-Return Valve (Check Valve) | - | - | 14.5 ~ 145 PSI (1 ~ 10 bar) | - | Air | Threaded | Control Valve | Free Hanging (In-Line) | - |
|
HB-1/8-QS-1/4-UCHECK VALVE |
2,657 |
|
Datasheet | HB | Bulk | Active | Non-Return Valve (Check Valve) | - | - | 14.5 ~ 145 PSI (1 ~ 10 bar) | - | Air | Threaded | Control Valve | Free Hanging (In-Line) | - |
|
HA-1/8-QS-1/4-UCHECK VALVE |
2,456 |
|
Datasheet | HA | Bulk | Active | Non-Return Valve (Check Valve) | - | - | 14.5 ~ 145 PSI (1 ~ 10 bar) | - | Air | Threaded | Control Valve | Free Hanging (In-Line) | - |
|
HE-2-3/8-QS-3/8-USHUT-OFF VALVE |
3,310 |
|
Datasheet | HE | Bulk | Active | Solenoid Valve | 2/2 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded 3/8" NPT | Solenoid Valve | Free Hanging (In-Line) | - |
|
HE-2-3/8-QS-10SHUT-OFF VALVE |
4,181 |
|
Datasheet | HE | Bulk | Active | Solenoid Valve | 2/2 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded 3/8" R | Solenoid Valve | Free Hanging (In-Line) | - |
|
HE-3-3/8-QS-10SHUT-OFF VALVE |
1,976 |
|
Datasheet | HE | Bulk | Active | Solenoid Valve | 3/2 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded 3/8" R | Solenoid Valve | Free Hanging (In-Line) | - |
|
HE-3-3/8-3/8-NPT-USHUT-OFF VALVE |
4,338 |
|
Datasheet | HE | Bulk | Active | Solenoid Valve | 3/2 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded 3/8" NPT | Solenoid Valve | Free Hanging (In-Line) | - |
|
HE-3-3/8-3/8SHUT-OFF VALVE |
2,764 |
|
Datasheet | HE | Bulk | Active | Solenoid Valve | 3/2 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded 3/8" R | Solenoid Valve | Free Hanging (In-Line) | - |
|
HE-3A-3/8-QS-3/8-USHUT-OFF VALVE |
3,806 |
|
Datasheet | HE | Bulk | Active | Solenoid Valve | 3/2 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded 3/8" NPT | Solenoid Valve | Free Hanging (In-Line) | - |
|
HE-3-3/8-QS-3/8-USHUT-OFF VALVE |
1,739 |
|
Datasheet | HE | Bulk | Active | Solenoid Valve | 3/2 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded 3/8" NPT | Solenoid Valve | Free Hanging (In-Line) | - |
Frequently Asked Questions
What are Valves and Control components used for?
Valves and Control components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Valves and Control part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Valves and Control parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.