ICMENU Electronics — Your one-stop global supplier of chips and electronic components.
ELECTRONIC COMPONENTS

Valves and Control

Explore Valves and Control parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.

For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Function Actuator Type Operating Pressure Orifice Diameter Fluid Type Connection Method For Use With/Related Products Mounting Type Features
81516200 Crouzet

81516200

CONTROL VALVE 4/2 SUBBASE MNT

Crouzet

1,328
Datasheet - Bulk Active Control Valve, Maintained 4/2 - 51 ~ 116 PSI (3.5 ~ 8 bar) 0.157" (4.00mm) Air, Inert Gas - - Sub-Base Mount -
81552101 Crouzet

81552101

SUB-BASE END DIN RAIL

Crouzet

2,989
Datasheet - Bulk Active Sub-Base, End - - - - - Push-In Connection for Tubing 5/32" (4.00mm) Dia Sequencer DIN Rail Pressure Indicator, Rotatable Connector
81735511 Crouzet

81735511

CONTROL VALVE 3/2 NC ROD MOUNT

Crouzet

4,291
Datasheet - Box Active Control Valve, Momentary 3/2 Normally Closed Pushbutton 30 ~ 116 PSI (2 ~ 8 bar) 0.106" (2.70mm) Air, Inert Gas Push-In Connection for Tubing 5/32" (4.00mm) Dia - Rod Mount Operating Force 8 ~ 18N
HGL-3/8-QS-8 Festo Corporation

HGL-3/8-QS-8

PILOTED CHECK VALVE

Festo Corporation

4,472
Datasheet - Bulk Active Non-Return Valve (Check Valve) - - 7 ~ 145 PSI (0.5 ~ 10 bar) - Air, Inert Gas, Liquid Threaded - Sub-Base Mount -
VUVS-L25-P53E-MD-N14-F8 Festo Corporation

VUVS-L25-P53E-MD-N14-F8

SOLENOID VALVE

Festo Corporation

4,487
Datasheet - Bulk Active Solenoid Valve - - 36 ~ 145 PSI (2.5 ~ 10 bar) - Air, Inert Gas, Liquid Threaded - Sub-Base Mount -
81513203 Crouzet

81513203

SOLENOID VALVE ASSY 4/2 DIN RAIL

Crouzet

3,474
Datasheet - Box Active Solenoid Valve Assembly 4/2 - 44 ~ 116 PSI (3 ~ 8 bar) 0.118" (3.00mm) Air, Inert Gas - - DIN Rail Manual Override, Supply Voltage 24VDC
81922210 Crouzet

81922210

POSITION DETECT 3/2 NC CHAS MNT

Crouzet

3,401
Datasheet Compact Bulk Active Position Detector 3/2 Normally Closed Side Rotary - No Lever 1 ~ 116PSI (0.1 ~ 8 bar) 0.118" (3.00mm) Air, Inert Gas Threaded 1/8" BSP - Chassis Mount Operating Force 25N
SOL1A4 Sensata Technologies, Inc.

SOL1A4

VALVE SOLENOID 3/8" BSP NO 220/2

Sensata Technologies, Inc.

1,586
Datasheet SOL Box Active Solenoid Valve 2/2 Normally Open, One-Way - 1 ~ 218 PSI (0.1 ~ 15 bar) - Inert Gas, Liquid Threaded 3/8" BSP - Free Hanging (In-Line) Supply Voltage 230VAC
81503725 Crouzet

81503725

TIMER ON-DELAY SUB-BASE MOUNT

Crouzet

4,727
Datasheet - Box Active Timer, Adjustable On-Delay - 30 ~ 116 PSI (2 ~ 8 bar) 0.106" (2.70mm) Air, Inert Gas - - Sub-Base Mount Delay Time 0.1 ~ 60sec
SOL6B1 Sensata Technologies, Inc.

SOL6B1

VALVE SOLENOID 1-1/2" BSP NC 24V

Sensata Technologies, Inc.

1,877
Datasheet SOL Box Active Solenoid Valve 2/2 Normally Closed, One-Way - 6 ~ 145 PSI (0.4 ~ 10 bar) - Inert Gas, Liquid Threaded 1-1/2" BSP - Free Hanging (In-Line) Supply Voltage 24VDC
SOL5A3 Sensata Technologies, Inc.

SOL5A3

VALVE SOLENOID 1-1/4" BSP NO 110

Sensata Technologies, Inc.

2,206
Datasheet SOL Box Active Solenoid Valve 2/2 Normally Open, One-Way - 6 ~ 174 PSI (0.4 ~ 12 bar) - Inert Gas, Liquid Threaded 1-1/4" BSP - Free Hanging (In-Line) Supply Voltage 110VAC
WATER-VALVE-6.5MM-12VDC Olimex LTD

WATER-VALVE-6.5MM-12VDC

WATER-VALVE-6.5MM-12VDC

Olimex LTD

4,401
Datasheet - Bulk Active Solenoid Valve - - 0 ~ 116PSI (0 ~ 8 bar) - Liquid Push-In Connection for Tubing 15/64" (6.00mm) Dia - Chassis Mount Supply Voltage 12VDC
VFOE-LE-T-R18-Q8 Festo Corporation

VFOE-LE-T-R18-Q8

ONE-WAY FLOW CONTROL VALVE

Festo Corporation

2,384
Datasheet VFOE Bulk Active Flow Restrictor, Adjustable One-Way - 3 ~ 145 PSI (0.2 ~ 10 bar) - Air Threaded 1/8" R - Sub-Base Mount -
VFOE-LE-T-M5-Q4 Festo Corporation

VFOE-LE-T-M5-Q4

ONE-WAY FLOW CONTROL VALVE

Festo Corporation

3,360
Datasheet VFOE Bulk Active Flow Restrictor, Adjustable One-Way - 3 ~ 145 PSI (0.2 ~ 10 bar) - Air Threaded M5 - Sub-Base Mount -
VFOE-LE-T-G18-Q8 Festo Corporation

VFOE-LE-T-G18-Q8

ONE-WAY FLOW CONTROL VALVE

Festo Corporation

1,413
Datasheet VFOE Bulk Active Flow Restrictor, Adjustable One-Way - 3 ~ 145 PSI (0.2 ~ 10 bar) - Air Threaded 1/8" G - Sub-Base Mount -
VFOE-LE-T-G18-Q6 Festo Corporation

VFOE-LE-T-G18-Q6

ONE-WAY FLOW CONTROL VALVE

Festo Corporation

4,019
Datasheet VFOE Bulk Active Flow Restrictor, Adjustable One-Way - 3 ~ 145 PSI (0.2 ~ 10 bar) - Air Threaded 1/8" G - Sub-Base Mount -
81545001 Crouzet

81545001

VAC GEN PRES OPERATED FREE HANG

Crouzet

1,633
Datasheet - Bulk Active Vacuum Generator Pressure Operated - 30 ~ 116 PSI (2 ~ 8 bar) - Air, Inert Gas Push-In Connection for Tubing 5/32" (4.00mm) Dia - Free Hanging (In-Line) -
81921714 Crouzet

81921714

POSITION DETECT 3/2 NC CHAS MNT

Crouzet

3,112
Datasheet Miniature Bulk Active Position Detector 3/2 Normally Closed Lever, Roller 1 ~ 116PSI (0.1 ~ 8 bar) 0.106" (2.70mm) Air, Inert Gas Push-In Connection for Tubing 5/32" (4.00mm) Dia - Chassis Mount Connectable Exhaust, Operating Force 18N
3-WAY-VALVE-12V Olimex LTD

3-WAY-VALVE-12V

3-WAY-VALVE-12V

Olimex LTD

1,718
Datasheet - Bulk Active Control Valve - - - - Air Threaded Control Valve Free Hanging (In-Line) -
VABF-L1-10H-H2 Festo Corporation

VABF-L1-10H-H2

CHECK VALVE

Festo Corporation

4,440
Datasheet - Bulk Active Non-Return Valve (Check Valve) - - 7.25 ~ 116 PSI (0.5 ~ 8 bar) - Air Threaded Control Valve Free Hanging (In-Line) -
Total 7416 Record«Prev1... 4748495051525354...371Next»
FAQ

Frequently Asked Questions

What are Valves and Control components used for?

Valves and Control components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Valves and Control part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Valves and Control parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Valves and Control?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top