Multiple Conductor Cables
Review Multiple Conductor Cables Cables, Wires components in this filtered selection. Compare manufacturer information, availability, pricing, datasheets and key specifications to narrow down suitable parts for your application.
If the exact part or specification you need is not listed, send the manufacturer part number, target parameters and quantity to ICMENU for sourcing and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Cable Type | Number of Conductors | Wire Gauge | Conductor Strand | Conductor Material | Jacket (Insulation) Material | Jacket (Insulation) Diameter | Shield Type | Length | Jacket Color | Ratings | Features | Voltage | Operating Temperature | Usage | Jacket (Insulation) Thickness | Conductor Insulation | Size / Dimension |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
16074.95.01CABLE 4COND 6AWG BLACK |
4,217 |
|
Datasheet | - | Bulk | Active | Multi-Conductor | 4 | 6 AWG | 133/27 | Copper, Bare | Carolprene | 1.080" (27.43mm) | - | - | Black | - | - | 600 V | -40°C ~ 90°C | Cord and Cordset | 0.0600" (1.524mm) | Ethylene Propylene Terpolymer Rubber (EPDM) | - |
|
09407.44.01ECABLE 7COND 14AWG BLACK 2500' |
1,260 |
|
Datasheet | - | Bulk | Active | Multi-Conductor | 7 | 14 AWG | 41/30 | Copper, Bare | Super Vu-Tron® | 0.710" (18.03mm) | - | 2500' (762.0m) | Black | - | - | 600 V | -40°C ~ 90°C | - | 0.0450" (1.143mm) | Ethylene Propylene Terpolymer Rubber (EPDM) | - |
|
09216.41.01ECABLE 16COND 12AWG BLACK 1000' |
4,649 |
|
Datasheet | - | Bulk | Active | Multi-Conductor | 16 | 12 AWG | 65/30 | Copper, Bare | Super Vu-Tron® | 1.135" (28.83mm) | - | 1000.0' (304.8m) | Black | - | - | 600 V | -40°C ~ 90°C | - | 0.0450" (1.143mm) | Ethylene Propylene Terpolymer Rubber (EPDM) | - |
|
09616.43.01CABLE 16COND 16AWG BLACK 2000' |
2,467 |
|
Datasheet | - | Bulk | Active | Multi-Conductor | 16 | 16 AWG | 26/30 | Copper, Bare | Super Vu-Tron® | 0.740" (18.80mm) | - | 2000.0' (609.6m) | Black | - | - | 600 V | -40°C ~ 90°C | - | 0.0300" (0.762mm) | Ethylene Propylene Terpolymer Rubber (EPDM) | - |
|
09410.43.01CABLE 10COND 14AWG BLACK 2000' |
1,389 |
|
Datasheet | - | Bulk | Active | Multi-Conductor | 10 | 14 AWG | 41/30 | Copper, Bare | Super Vu-Tron® | 0.820" (20.83mm) | - | 2000.0' (609.6m) | Black | - | - | 600 V | -40°C ~ 90°C | - | 0.0450" (1.143mm) | Ethylene Propylene Terpolymer Rubber (EPDM) | - |
|
09410.52.01CABLE 10COND 14AWG BLACK 3000' |
2,545 |
|
Datasheet | - | Bulk | Active | Multi-Conductor | 10 | 14 AWG | 41/30 | Copper, Bare | Super Vu-Tron® | 0.820" (20.83mm) | - | 3000' (914.4m) | Black | - | - | 600 V | -40°C ~ 90°C | - | 0.0450" (1.143mm) | Ethylene Propylene Terpolymer Rubber (EPDM) | - |
|
09416.52.01CABLE 16COND 14AWG BLACK 3000' |
3,557 |
|
Datasheet | - | Bulk | Active | Multi-Conductor | 16 | 14 AWG | 41/30 | Copper, Bare | Super Vu-Tron® | 1.030" (26.16mm) | - | 3000' (914.4m) | Black | - | - | 600 V | -40°C ~ 90°C | - | 0.0450" (1.143mm) | Ethylene Propylene Terpolymer Rubber (EPDM) | - |
|
09212.52.01CABLE 12COND 12AWG BLACK 3000' |
1,151 |
|
Datasheet | - | Bulk | Active | Multi-Conductor | 12 | 12 AWG | 65/30 | Copper, Bare | Super Vu-Tron® | 1.010" (25.65mm) | - | 3000' (914.4m) | Black | - | - | 600 V | -40°C ~ 90°C | - | 0.0450" (1.143mm) | Ethylene Propylene Terpolymer Rubber (EPDM) | - |
|
16095.41.01CABLE 5COND 2AWG BLACK 1000' |
2,084 |
|
Datasheet | - | Bulk | Active | Multi-Conductor | 5 | 2 AWG | 133/23 | Copper, Bare | Carolprene | 1.580" (40.13mm) | - | 1000.0' (304.8m) | Black | - | - | 600 V | -40°C ~ 90°C | - | 0.0600" (1.524mm) | Ethylene Propylene Terpolymer Rubber (EPDM) | - |
|
2131474MULT-PAIR 600CON 24AWG NAT 1000' |
1,967 |
|
Datasheet | - | Spool | Active | Multi-Pair | 600 (300 Pair Twisted) | 24 AWG | Solid | Copper, Bare | Polyvinylidene Fluoride (PVDF) | 1.450" (36.83mm) | - | 1000.0' (304.8m) | Natural | - | Rip Cord | - | -10°C ~ 75°C | - | - | Poly-Vinyl Chloride (PVC) | - |
Frequently Asked Questions
What are Multiple Conductor Cables components used for?
Multiple Conductor Cables components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Multiple Conductor Cables part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Multiple Conductor Cables parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.