ICMENU Electronics — Your one-stop global supplier of chips and electronic components.
FILTERED COMPONENT SELECTION

Multiple Conductor Cables

Review Multiple Conductor Cables Cables, Wires components in this filtered selection. Compare manufacturer information, availability, pricing, datasheets and key specifications to narrow down suitable parts for your application.

If the exact part or specification you need is not listed, send the manufacturer part number, target parameters and quantity to ICMENU for sourcing and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Cable Type Number of Conductors Wire Gauge Conductor Strand Conductor Material Jacket (Insulation) Material Jacket (Insulation) Diameter Shield Type Length Jacket Color Ratings Features Voltage Operating Temperature Usage Jacket (Insulation) Thickness Conductor Insulation Size / Dimension
C1802.25.07 Prysmian Group

C1802.25.07

CABLE SPKR 2COND 14AWG BLUE 500'

Prysmian Group

3,910
Datasheet - Spool Obsolete Speaker 2 14 AWG 105/34 Copper, Bare Poly-Vinyl Chloride (PVC) 0.226" (5.74mm) - 500.0' (152.4m) Blue - - 300 V -20°C ~ 60°C Audio-Video, Home 0.0210" (0.533mm) Polypropylene (PP) -
C3204.41.86 Prysmian Group

C3204.41.86

CABLE 2COND 22AWG NATURAL 1000'

Prysmian Group

4,568
Datasheet - Spool Obsolete Multi-Conductor 2 (1 Pair Twisted) 22 AWG 7/30 Copper, Tinned Fluoropolymer 0.117" (2.97mm) Foil 1000.0' (304.8m) Natural - Drain Wire 300 V -40°C ~ 150°C Communication, Control 0.0098" (0.250mm) Fluoropolymer -
E1514S.41.03 Prysmian Group

E1514S.41.03

CABLE 4COND 16AWG RED 500'

Prysmian Group

4,984
Datasheet - Bulk Active Multi-Conductor 4 16 AWG Solid Copper, Annealed Bare Poly-Vinyl Chloride (PVC) 0.202" (5.13mm) - 500.0' (152.4m) Red ASTM B-3 Rip Cord 300 V -20°C ~ 75°C Alarm, Safety 0.0150" (0.381mm) Poly-Vinyl Chloride (PVC) -
C0458A.41.10 Prysmian Group

C0458A.41.10

CABLE 2COND 14AWG GRAY SHLD 100'

Prysmian Group

3,962
Datasheet - Bulk Active Multi-Conductor 2 14 AWG 19/0.0147" Copper, Annealed Tinned Poly-Vinyl Chloride (PVC) 0.288" (7.32mm) Foil 100.0' (30.5m) Gray ASTM B-33 Drain Wire 300 V -20°C ~ 105°C Communication, Control 0.0420" (1.067mm) Poly-Vinyl Chloride (PVC) -
E2204S.41.04 Prysmian Group

E2204S.41.04

4C/18 7/26BC OA SH CMP/CL3P

Prysmian Group

2,037
Datasheet - Bulk Active Multi-Conductor 4 18 AWG 7/26 Copper, Bare Poly-Vinyl Chloride (PVC) 0.185" (4.70mm) Foil, Braid 1000.0' (304.8m) Orange - - 300 V 0°C ~ 75°C - 0.0150" (0.381mm) Poly-Vinyl Chloride (PVC) -
C9133A.41.10 Prysmian Group

C9133A.41.10

CABLE 8COND 18AWG GRAY SHLD 100'

Prysmian Group

4,512
Datasheet Exzel™ Bulk Discontinued at Digi-Key Multi-Conductor 8 18 AWG 16/30 Copper, Tinned Poly-Vinyl Chloride (PVC) 0.332" (8.43mm) Foil 100.0' (30.5m) Gray - Drain Wire, Rip Cord 300 V -30°C ~ 105°C - 0.0320" (0.813mm) Poly-Vinyl Chloride (PVC) -
E3522S.41.0301 Prysmian Group

E3522S.41.0301

2C/14 SBC PVC/NS/FLEX FPLP

Prysmian Group

4,420
Datasheet - Bulk Active - - - - - - - - - - - - - - - - - -
02765.38.01 Prysmian Group

02765.38.01

CABLE 3COND 16AWG BLACK 500'

Prysmian Group

3,416
Datasheet - Spool Active Multi-Conductor 3 16 AWG 26/30 Copper, Bare Carolprene 0.390" (9.91mm) - 500.0' (152.4m) Black - - 600 V -40°C ~ 90°C Cord and Cordset 0.0300" (0.762mm) Ethylene Propylene Terpolymer Rubber (EPDM) -
E2522S.41.03 Prysmian Group

E2522S.41.03

CABLE 2COND 16AWG RED SHLD 500'

Prysmian Group

2,929
Datasheet - Spool Active Multi-Conductor 2 16 AWG Solid Copper, Annealed Bare Poly-Vinyl Chloride (PVC) 0.180" (4.57mm) Foil 500.0' (152.4m) Red ASTM B-3 Drain Wire, Rip Cord 300 V -20°C ~ 75°C Alarm, Safety 0.0150" (0.381mm) Poly-Vinyl Chloride (PVC) -
C2688A.41.10 Prysmian Group

C2688A.41.10

CABLE 4COND 18AWG GRAY SHLD 100'

Prysmian Group

1,671
Datasheet - Bulk Discontinued at Digi-Key Multi-Conductor 4 18 AWG 16/30 Copper, Annealed Tinned Poly-Vinyl Chloride (PVC) 0.286" (7.26mm) Braid 100.0' (30.5m) Gray ASTM B-33 - 300 V -20°C ~ 80°C Communication, Control 0.0320" (0.813mm) Poly-Vinyl Chloride (PVC) -
Total 3802 Record«Prev1... 277278279280281282283284...381Next»
FAQ

Frequently Asked Questions

What are Multiple Conductor Cables components used for?

Multiple Conductor Cables components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Multiple Conductor Cables part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find Multiple Conductor Cables parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

PART MATCHING & SOURCING

Need Help Narrowing Down the Right Multiple Conductor Cables Part?

Send your target specifications, preferred manufacturer, quantity or reference part number. Our team can help check matching options, availability and quotation details for your sourcing requirement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top