Industrial, DIN Rail Power Supplies
Review Industrial, DIN Rail Power Supplies Power Supplies - External/Internal (Off-Board) components in this filtered selection. Compare manufacturer information, availability, pricing, datasheets and key specifications to narrow down suitable parts for your application.
If the exact part or specification you need is not listed, send the manufacturer part number, target parameters and quantity to ICMENU for sourcing and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Input Type | Number of Outputs | AC Voltage - Input | DC Voltage - Input (Min) | DC Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Efficiency | Operating Temperature | Features | Approval Agency | Standard Number |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TIS 600-148 REDAC/DC DIN RAIL SUPPLY 48V 576W |
2,035 |
|
Datasheet | TIS (600W) | Box | Obsolete | AC | 1 | 93 ~ 132 VAC, 187 ~ 264 VAC | - | - | 48V | - | - | - | - | - | 12A | 576W | - | Hazardous Locations, Industrial, ITE (Commercial) | 90% | -25°C ~ 70°C (With Derating) | Adjustable Output, IP20, Load Sharing | CB, CE, cCSAus, cULus, cURus | - |
|
TIS 600-148 SIGAC/DC DIN RAIL SUPPLY 48V 576W |
3,457 |
|
Datasheet | TIS (600W) | Box | Obsolete | AC | 1 | 93 ~ 132 VAC, 187 ~ 264 VAC | - | - | 48V | - | - | - | - | - | 12A | 576W | - | Hazardous Locations, Industrial, ITE (Commercial) | 90% | -25°C ~ 70°C (With Derating) | Adjustable Output, IP20, Remote On/Off | CB, CE, cCSAus, cULus, cURus | - |
|
TIS 75-112AC/DC DIN RAIL SUPPLY 12V 72W |
2,183 |
|
Datasheet | TIS (75W) | Box | Obsolete | AC | 1 | 93 ~ 132 VAC, 187 ~ 264 VAC | - | - | 12V | - | - | - | - | - | 6A | 72W | - | Hazardous Locations, Industrial, ITE (Commercial) | 85% | -25°C ~ 70°C (With Derating) | Adjustable Output, IP20 | CB, CE, cCSAus, cULus, cURus | - |
|
TIS 75-148AC/DC DIN RAIL SUPPLY 48V 72W |
3,546 |
|
Datasheet | TIS (75W) | Box | Obsolete | AC | 1 | 93 ~ 132 VAC, 187 ~ 264 VAC | - | - | 48V | - | - | - | - | - | 1.5A | 72W | - | Hazardous Locations, Industrial, ITE (Commercial) | 85% | -25°C ~ 70°C (With Derating) | Adjustable Output, IP20 | CB, CE, cCSAus, cULus, cURus | - |
|
TIS 150-124AC/DC DIN RAIL SUPPLY 24V 144W |
2,179 |
|
Datasheet | TIS (150W) | Box | Obsolete | AC | 1 | 93 ~ 132 VAC, 187 ~ 264 VAC | - | - | 24V | - | - | - | - | - | 6A | 144W | - | Hazardous Locations, Industrial, ITE (Commercial) | 85% | -25°C ~ 70°C (With Derating) | Adjustable Output, IP20 | CB, CE, cCSAus, cULus, cURus | - |
|
TIS 300-124AC/DC DIN RAIL SUPPLY 24V 288W |
3,259 |
|
Datasheet | TIS (300W) | Box | Obsolete | AC | 1 | 93 ~ 132 VAC, 187 ~ 264 VAC | - | - | 24V | - | - | - | - | - | 12A | 288W | - | Hazardous Locations, Industrial, ITE (Commercial) | 85% | -25°C ~ 70°C (With Derating) | Adjustable Output, IP20 | CB, CE, cCSAus, cULus, cURus | - |
|
TIS 75-124AC/DC DIN RAIL SUPPLY 24V 72W |
4,758 |
|
Datasheet | TIS (75W) | Box | Obsolete | AC | 1 | 93 ~ 132 VAC, 187 ~ 264 VAC | - | - | 24V | - | - | - | - | - | 3A | 72W | - | Hazardous Locations, Industrial, ITE (Commercial) | 85% | -25°C ~ 70°C (With Derating) | Adjustable Output, IP20 | CB, CE, cCSAus, cULus, cURus | - |
|
TIS 300-172AC/DC DIN RAIL SUPPLY 72V 302W |
1,799 |
|
Datasheet | TIS (300W) | Box | Obsolete | AC | 1 | 93 ~ 132 VAC, 187 ~ 264 VAC | - | - | 72V | - | - | - | - | - | 4.2A | 302W | - | Hazardous Locations, Industrial, ITE (Commercial) | 85% | -25°C ~ 70°C (With Derating) | Adjustable Output, IP20 | CB, CE, cCSAus, cULus, cURus | - |
|
TIS 600-172AC/DC DIN RAIL SUPPLY 72V 612W |
4,950 |
|
Datasheet | TIS (600W) | Box | Obsolete | AC | 1 | 93 ~ 132 VAC, 187 ~ 264 VAC | - | - | 72V | - | - | - | - | - | 8.5A | 612W | - | Hazardous Locations, Industrial, ITE (Commercial) | 90% | -25°C ~ 70°C (With Derating) | Adjustable Output, IP20 | CB, CE, cCSAus, cULus, cURus | - |
Frequently Asked Questions
What are Industrial, DIN Rail Power Supplies components used for?
Industrial, DIN Rail Power Supplies components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Industrial, DIN Rail Power Supplies part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Industrial, DIN Rail Power Supplies parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.