Single IGBTs
Explore Single IGBTs parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | IGBT Type | Voltage - Collector Emitter Breakdown (Max) | Current - Collector (Ic) (Max) | Current - Collector Pulsed (Icm) | Vce(on) (Max) @ Vge, Ic | Power - Max | Switching Energy | Input Type | Gate Charge | Td (on/off) @ 25°C | Test Condition | Reverse Recovery Time (trr) | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
IHW30N135R5XKSA1IGBT TRENCH FS 1350V 60A TO247-3 |
106 |
|
Datasheet | TrenchStop™ | TO-247-3 | Tube | Active | Trench Field Stop | 1350 V | 60 A | 90 A | 1.95V @ 15V, 30A | 330 W | 1.4mJ (off) | Standard | 235 nC | -/310ns | 600V, 30A, 10Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3 |
|
IGW15N120H3FKSA1IGBT TRENCH FS 1200V 30A TO247-3 |
216 |
|
Datasheet | TrenchStop® | TO-247-3 | Tube | Active | Trench Field Stop | 1200 V | 30 A | 60 A | 2.4V @ 15V, 15A | 217 W | 1.55mJ | Standard | 75 nC | 21ns/260ns | 600V, 15A, 35Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3-1 |
|
STGWA60V60DFIGBT TRENCH FS 600V 80A TO247 |
700 |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 600 V | 80 A | 240 A | 2.3V @ 15V, 60A | 375 W | 750µJ (on), 550µJ (off) | Standard | 334 nC | 60ns/208ns | 400V, 60A, 4.7Ohm, 15V | 74 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 Long Leads |
|
STGW20NC60VIGBT 600V 60A TO247-3 |
557 |
|
Datasheet | PowerMESH™ | TO-247-3 | Tube | Active | - | 600 V | 60 A | 100 A | 2.5V @ 15V, 20A | 200 W | 220µJ (on), 330µJ (off) | Standard | 100 nC | 31ns/100ns | 390V, 20A, 3.3Ohm, 15V | - | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-247-3 |
|
IXGH36N60B3IGBT PT 600V 92A TO247AD |
121 |
|
Datasheet | GenX3™ | TO-247-3 | Tube | Active | PT | 600 V | 92 A | 200 A | 1.8V @ 15V, 30A | 250 W | 540µJ (on), 800µJ (off) | Standard | 80 nC | 19ns/125ns | 400V, 30A, 5Ohm, 15V | - | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-247AD |
|
IXXH30N60B3D1IGBT 600V 60A 270W TO247 |
294 |
|
Datasheet | GenX3™, XPT™ | TO-247-3 | Tube | Active | PT | 600 V | 60 A | 115 A | 1.85V @ 15V, 24A | 270 W | 550µJ (on), 500µJ (off) | Standard | 39 nC | 23ns/97ns | 400V, 24A, 10Ohm, 15V | 25 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247AD (IXXH) |
|
IKB40N65EH5ATMA1IGBT TRENCH FS 650V 74A TO263-3 |
998 |
|
Datasheet | TrenchStop™ 5 | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Trench Field Stop | 650 V | 74 A | 160 A | 2.1V @ 15V, 40A | 250 W | 1.1mJ (on), 400µJ (off) | Standard | 95 nC | 20ns/157ns | 400V, 40A, 15Ohm, 15V | 78 ns | -40°C ~ 175°C (TJ) | - | - | Surface Mount | PG-TO263-3 |
|
IKW30N60TFKSA1IGBT TRENCH FS 600V 60A TO247-3 |
6,324 |
|
Datasheet | TrenchStop® | TO-247-3 | Tube | Active | Trench Field Stop | 600 V | 60 A | 90 A | 2.05V @ 15V, 30A | 187 W | 1.46mJ | Standard | 167 nC | 23ns/254ns | 400V, 30A, 10.6Ohm, 15V | 143 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3-1 |
|
IGB50N60TATMA1IGBT TRENCH 600V 100A TO263-3 |
2,801 |
|
Datasheet | TrenchStop® | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Trench | 600 V | 100 A | 150 A | 2V @ 15V, 50A | 333 W | 2.6mJ | Standard | 310 nC | 26ns/299ns | 400V, 50A, 7Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Surface Mount | PG-TO263-3-2 |
|
STGW60H65DFBIGBT TRENCH FS 650V 80A TO247 |
530 |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 650 V | 80 A | 240 A | 2V @ 15V, 60A | 375 W | 1.09mJ (on), 626µJ (off) | Standard | 306 nC | 51ns/160ns | 400V, 60A, 5Ohm, 15V | 60 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 |
|
FGA40N65SMDIGBT FIELD STOP 650V 80A TO3PN |
340 |
|
Datasheet | - | TO-3P-3, SC-65-3 | Tube | Active | Field Stop | 650 V | 80 A | 120 A | 2.5V @ 15V, 40A | 349 W | 820µJ (on), 260µJ (off) | Standard | 119 nC | 12ns/92ns | 400V, 40A, 6Ohm, 15V | 42 ns | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-3PN |
|
IHW40N135R5XKSA1IGBT TRENCH FS 1350V 80A TO247-3 |
136 |
|
Datasheet | TrenchStop™ | TO-247-3 | Tube | Active | Trench Field Stop | 1350 V | 80 A | 120 A | 1.95V @ 15V, 40A | 394 W | 2mJ (off) | Standard | 305 nC | -/410ns | 600V, 40A, 10Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3 |
|
|
IKW40N65H5FKSA1IGBT 650V 74A TO247-3 |
850 |
|
Datasheet | TrenchStop® | TO-247-3 | Tube | Active | - | 650 V | 74 A | 120 A | 2.1V @ 15V, 40A | 255 W | 390µJ (on), 120µJ (off) | Standard | 95 nC | 22ns/165ns | 400V, 20A, 15Ohm, 15V | 62 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3 |
|
STGW40H60DLFBIGBT 600V 80A 283W TO-247 |
450 |
|
Datasheet | - | TO-247-3 | Tube | Active | Trench Field Stop | 600 V | 80 A | 160 A | 2V @ 15V, 40A | 283 W | 363µJ (off) | Standard | 210 nC | -/142ns | 400V, 40A, 10Ohm, 15V | - | -55°C ~ 175°C (TJ) | - | - | Through Hole | TO-247 |
|
|
IGW50N65F5FKSA1IGBT 650V 80A TO247-3 |
199 |
|
Datasheet | TrenchStop® | TO-247-3 | Tube | Active | - | 650 V | 80 A | 150 A | 2.1V @ 15V, 50A | 305 W | 490µJ (on), 160µJ (off) | Standard | 120 nC | 21ns/175ns | 400V, 25A, 12Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3 |
|
|
IKW50N65H5FKSA1IGBT 650V 80A TO247-3 |
423 |
|
Datasheet | TrenchStop® | TO-247-3 | Tube | Active | - | 650 V | 80 A | 150 A | 2.1V @ 15V, 50A | 305 W | 520µJ (on), 180µJ (off) | Standard | 120 nC | 21ns/180ns | 400V, 25A, 12Ohm, 15V | 57 ns | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3 |
|
FGH40N60UFDTUIGBT FIELD STOP 600V 80A TO247-3 |
1,173 |
|
Datasheet | - | TO-247-3 | Tube | Active | Field Stop | 600 V | 80 A | 120 A | 2.4V @ 15V, 40A | 290 W | 1.19mJ (on), 460µJ (off) | Standard | 120 nC | 24ns/112ns | 400V, 40A, 10Ohm, 15V | 45 ns | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-247-3 |
|
STGW30NC60WDIGBT 600V 60A TO247-3 |
575 |
|
Datasheet | PowerMESH™ | TO-247-3 | Tube | Active | - | 600 V | 60 A | 150 A | 2.5V @ 15V, 20A | 200 W | 305µJ (on), 181µJ (off) | Standard | 102 nC | 29.5ns/118ns | 390V, 20A, 10Ohm, 15V | 40 ns | -55°C ~ 150°C (TJ) | - | - | Through Hole | TO-247-3 |
|
IGW25N120H3FKSA1IGBT TRENCH FS 1200V 50A TO247-3 |
2,912 |
|
Datasheet | TrenchStop® | TO-247-3 | Tube | Active | Trench Field Stop | 1200 V | 50 A | 100 A | 2.4V @ 15V, 25A | 326 W | 2.65mJ | Standard | 115 nC | 27ns/277ns | 600V, 25A, 23Ohm, 15V | - | -40°C ~ 175°C (TJ) | - | - | Through Hole | PG-TO247-3-1 |
|
AIGB50N65F5ATMA1DISCRETE SWITCHES |
1,090 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | NPT | 650 V | 50 A | - | - | - | - | Standard | - | - | - | - | - | - | - | Surface Mount | PG-TO263-3-2 |
Frequently Asked Questions
What are Single IGBTs components used for?
Single IGBTs components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Single IGBTs part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Single IGBTs parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.