Heavy Duty Connector Inserts, Modules
Explore Heavy Duty Connector Inserts, Modules parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Connector Type | Gender | Number of Positions | Size | Termination Style | Voltage Rating | Current Rating (Amps) | Contact Type | Operating Temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0936010536S-M 16/6 M INS CRP 6P 16A 500V |
0 |
|
Datasheet | GWconnect | Bulk | Active | Insert without Contacts | Male | 6+Ground | - | Crimp | 500V | 16A | - | -40°C ~ 125°C |
|
C146 10A006 600 15PIN MODULE 6 POLE |
0 |
|
Datasheet | heavymate® | Bulk | Active | Module without Contacts | Male | 6 | - | Crimp | 630V | 16A | - | -40°C ~ 125°C |
|
C146 10B002 900 15MODULE W/O CONTACTS FEMALE 2POS |
0 |
|
Datasheet | heavymate® | Bulk | Active | Module without Contacts | Female | 2 | - | - | 50V | - | - | -40°C ~ 124°C |
|
0936010555S-M 10/12 M INS CRP 12P 10A 250V |
0 |
|
Datasheet | GWconnect | Bulk | Active | Insert without Contacts | Male | 12+Ground | - | Crimp | 250V | 10A | - | -40°C ~ 125°C |
|
1908530000MODULE W/O CONTACTS MALE 6POS |
0 |
|
Datasheet | Rockstar® ConCept | Bulk | Active | Module without Contacts | Male | 6 (2 + 4 Power) | - | - | - | - | - | -40°C ~ 125°C |
|
C146 10B002 600 15SOCKET MODULE FOR TURNED CONTACT |
0 |
|
Datasheet | heavymate® | Bulk | Active | Insert without Contacts | Female | 2 | - | Crimp | 1000V | 100A | - | -40°C ~ 125°C |
|
0936010529S-M 40/4 F INS CRP 4P 40A 830V |
0 |
|
Datasheet | GWconnect | Bulk | Active | Insert without Contacts | Female | 4+Ground | - | Crimp | 830V | 40A | - | -40°C ~ 125°C |
|
0936010525S-M 40/3C F INS CRP 3P 40A 500V |
0 |
|
Datasheet | GWconnect | Bulk | Active | Insert without Contacts | Female | 3+Ground | - | Crimp | 500V | 40A | - | -40°C ~ 125°C |
|
0936010526S-M 40/3C M INS CRP 3P 40A 500V |
0 |
|
Datasheet | GWconnect | Bulk | Active | Insert without Contacts | Male | 3+Ground | - | Crimp | 500V | 40A | - | -40°C ~ 125°C |
|
0936010530S-M 40/4 M INS CRP 4P 40A 830V |
0 |
|
Datasheet | GWconnect | Bulk | Active | Insert without Contacts | Male | 4+Ground | - | Crimp | 830V | 40A | - | -40°C ~ 125°C |
|
0511920600INSERT W/OUT CONTACTS MALE 6POS |
3 |
|
Datasheet | HMC | Bulk | Obsolete | Insert without Contacts | Male | 6 | - | - | 250V | - | Mini-Fit Jr 5558 | -55°C ~ 125°C |
|
0936010446S-QD8/0 16A 500V SP+PE MALE INSE |
0 |
|
Datasheet | GWconnect S-QD | Bulk | Active | Insert without Contacts | Male | 8+Ground | - | Crimp | 500V | 16A | - | -40°C ~ 125°C |
|
C146 A01 001 E8MODULE MALE 1POS CRIMP |
0 |
|
Datasheet | heavy|mate®, C146 M | Bulk | Active | Module without Contacts | Male | 1 | - | Crimp | 1000V | 150A | heavy|mate®, C146 M | -40°C ~ 125°C |
|
C14610A0070002CINSERT MALE 7P+1GND CRIMP 100PCS |
0 |
|
Datasheet | heavymate® | Bulk | Active | Insert without Contacts | Male | 7+Ground | A3/4 | Crimp | 600V | 15A | C 16-3; heavy|mate®, C146 D, M | -40°C ~ 125°C |
|
0936010504S-M RJ45 M INS ADT |
0 |
|
Datasheet | GWconnect | Bulk | Active | Insert with RJ45 | Male | 8p8c | - | IDC | 50V | 1A | - | -40°C ~ 85°C |
|
0936010520S-M PN2 PNEUMATIC CONN. ADT 2 CN |
0 |
|
Datasheet | GWconnect | Bulk | Active | Module, Pneumatic | Female/Male | 2 | - | - | - | - | - | -40°C ~ 80°C |
|
1425006HEAVYCON MALE INSERT, D7 SERIES, |
0 |
|
Datasheet | HEAVYCON® D | Bulk | Active | Insert | Male | 7+Ground | D7 | Crimp | 42V | 10A | CK 1.6-ED | -40°C ~ 125°C |
|
KN01M14PKSInterconnect Rectangular |
0 |
|
Datasheet | KN01 | Bulk | Active | Module without Contacts | Male | 14 | M | Crimp | 24V | 3A | - | -20°C ~ 105°C |
|
|
0511940800INSERT W/OUT CONTACTS MALE 8POS |
0 |
|
Datasheet | HMC | Bulk | Obsolete | Insert without Contacts | Male | 8 | - | - | - | - | - | -55°C ~ 125°C |
|
KN01M16SHInterconnect Rectangular |
0 |
|
Datasheet | KN01 | Bulk | Active | Module without Contacts | Female | 16 | M | Crimp | 250V | 16A | - | -20°C ~ 105°C |
Frequently Asked Questions
What are Heavy Duty Connector Inserts, Modules components used for?
Heavy Duty Connector Inserts, Modules components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Heavy Duty Connector Inserts, Modules part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Heavy Duty Connector Inserts, Modules parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.