DC Brushless Fans (BLDC)
Explore DC Brushless Fans (BLDC) parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Voltage - Rated | Size / Dimension | Width | Air Flow | Static Pressure | Bearing Type | Fan Type | Features | Noise | Power (Watts) | RPM | Termination | Ingress Protection | Operating Temperature | Approval Agency | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
9WL0948P1H601FAN AXIAL 92X38MM 48VDC WIRE |
4,949 |
|
Datasheet | San Ace 92W | Bulk | Active | 48VDC | Square - 92mm L x 92mm H | 38.00mm | 130.6 CFM (3.66m³/min) | 1.726 in H2O (429.9 Pa) | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | 61.0dB(A) | 23.04 W | 9000 RPM | 4 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 0.661 lb (299.82 g) |
|
DV4114NFAN AXIAL 119X38MM 24VDC WIRE |
352 |
|
Datasheet | DV4100 | Bulk | Active | 24VDC | Square - 119mm L x 119mm H | 38.00mm | 164.9 CFM (4.62m³/min) | - | Ball | Tubeaxial | Locked Rotor Protection | 61.0dB(A) | 20.5 W | 6000 RPM | 2 Wire Leads | - | -4 ~ 149°F (-20 ~ 65°C) | CE, CSA, UL, VDE | 0.827 lb (375.12 g) |
|
RLF100-11/14FAN BLOWER CF 127X25.4MM 24VDC |
379 |
|
Datasheet | RLF100 | Bulk | Active | 24VDC | Square/Rounded - 127mm L x 127mm H | 25.40mm | 37.7 CFM (1.06m³/min) | - | Ball | Blower, Centrifugal | Locked Rotor Protection | 60.0dB(A) | 8 W | 5100 RPM | 2 Wire Leads | - | -4 ~ 167°F (-20 ~ 75°C) | - | 0.705 lb (319.78 g) |
|
4114NH6FAN AXIAL 119X38MM 24VDC WIRE |
2,525 |
|
Datasheet | 4100N | Bulk | Active | 24VDC | Square - 119mm L x 119mm H | 38.00mm | 259.0 CFM (7.25m³/min) | - | Ball | Tubeaxial | - | 73.0dB(A) | 65 W | 8400 RPM | 2 Wire Leads | - | -4 ~ 149°F (-20 ~ 65°C) | CSA, UL, VDE | 0.86 lb (390.09 g) |
|
9GT0812P4S001FAN AXIAL 80X25MM 12VDC WIRE |
681 |
|
Datasheet | San Ace 80T | Box | Active | 12VDC | Square - 80mm L x 80mm H | 25.00mm | 65.7 CFM (1.84m³/min) | 0.574 in H2O (143.0 Pa) | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | 46.0dB(A) | 5.52 W | 6700 RPM | 4 Wire Leads | - | -40 ~ 185°F (-40 ~ 85°C) | CSA, TUV, UL | 0.287 lb (130.18 g) |
|
ODB182-24HBFAN BLOWER 171X82MM 24VDC WIRE |
439 |
|
Datasheet | ODB182 | Box | Active | 24VDC | Rectangular/Rounded - 171mm L x 182.1mm H | 82.00mm | 136.0 CFM (3.81m³/min) | 2.500 in H2O (622.7 Pa) | Ball | Blower | - | 63.0dB | - | 2000 RPM | 2 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | cURus | 2.5 lbs (1.1 kg) |
|
109E4724H401FAN AXIAL 172X25.4MM 24VDC WIRE |
151 |
|
Datasheet | San Ace 172 | Box | Active | 24VDC | Rectangular/Rounded - 172mm L x 147mm H | 25.40mm | 226.0 CFM (6.33m³/min) | 0.542 in H2O (135.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 57.0dB(A) | 24 W | 3400 RPM | 3 Wire Leads | - | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 1.1 lbs (500.0 g) |
|
9GT0912P4J001FAN AXIAL 92X25MM 12VDC WIRE |
106 |
|
Datasheet | San Ace 92T | Box | Active | 12VDC | Square - 92mm L x 92mm H | 25.00mm | 77.7 CFM (2.18m³/min) | 0.420 in H2O (104.6 Pa) | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | 44.0dB(A) | 5.04 W | 5000 RPM | 4 Wire Leads | - | -40 ~ 185°F (-40 ~ 85°C) | CSA, TUV, UL | 0.331 lb (150.14 g) |
|
OD254AP-24HBFAN AXIAL 254X89MM 24VDC WIRE |
543 |
|
Datasheet | OD254 | Box | Active | 24VDC | Round - 254mm Dia | 89.00mm | 850.0 CFM (23.80m³/min) | 0.830 in H2O (206.7 Pa) | Ball | Tubeaxial | Auto Restart | 64.0dB | 64 W | 2500 RPM | 2 Wire Leads | - | -4 ~ 167°F (-20 ~ 75°C) | cURus, TUV | - |
|
RG125-19/14N/2FAN BLOWER CF 180X40MM 24VDC |
296 |
|
Datasheet | RG125N | Box | Active | 24VDC | Square - 180mm L x 180mm H | 40.00mm | 51.5 CFM (1.44m³/min) | - | Ball | Blower, Centrifugal | Speed Sensor (Tach) | 58.0dB(A) | 5 W | 2550 RPM | 3 Wire Leads | - | -22 ~ 167°F (-30 ~ 75°C) | - | 1.6 lbs (725.7 g) |
|
9HV1248P1G001FAN AXIAL 119X38MM 48VDC WIRE |
3,856 |
|
Datasheet | San Ace 120 | Box | Active | 48VDC | Square - 119mm L x 119mm H | 38.00mm | 293.0 CFM (8.20m³/min) | 5.220 in H2O (1300.3 Pa) | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | 75.0dB(A) | 96 W | 11500 RPM | 4 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL | 1 lb (453.6 g) |
|
19031235AFAN AXIAL 172X50.8MM 48V PQ48B7 |
288 |
|
Datasheet | Patriot | Box | Active | 48VDC | Round - 172mm Dia | 50.80mm | 235.0 CFM (6.58m³/min) | 0.769 in H2O (191.5 Pa) | Ball | Tubeaxial | Auto Restart, Locked Rotor Protection, Speed Sensor (Tach) | 51.2dB(A) | 22 W | 3475 RPM | 3 Wire Leads | - | 14 ~ 158°F (-10 ~ 70°C) | CE, cUL, UL | 1.9 lbs (861.8 g) |
|
4114N/2H6PFAN AXIAL 119X38MM 24VDC WIRE |
360 |
|
Datasheet | 4100N, S-Force | Bulk | Active | 24VDC | Square - 119mm L x 119mm H | 38.00mm | 259.0 CFM (7.25m³/min) | - | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | 59.0dB(A) | - | - | 4 Wire Leads | - | - | - | - |
|
9GT0924P1M001FAN AXIAL 92X38MM 24VDC WIRE |
337 |
|
Datasheet | San Ace 92T | Box | Active | 24VDC | Square - 92mm L x 92mm H | 38.00mm | 116.5 CFM (3.26m³/min) | 1.260 in H2O (313.9 Pa) | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | 58.0dB(A) | 18 W | 8100 RPM | 4 Wire Leads | - | -40 ~ 185°F (-40 ~ 85°C) | CSA, TUV, UL | 0.595 lb (269.89 g) |
|
109E5724C501FAN AXIAL 172X51MM 24VDC WIRE |
2,168 |
|
Datasheet | San Ace 172 | Box | Active | 24VDC | Rectangular/Rounded - 172mm L x 150mm H | 51.00mm | 350.0 CFM (9.80m³/min) | 1.237 in H2O (308.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 66.0dB(A) | 55.2 W | 4800 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.7 lbs (760.0 g) |
|
5114NFAN AXIAL 135X38MM 24VDC WIRE |
260 |
|
Datasheet | 5100N | Box | Active | 24VDC | Square - 135mm L x 135mm H | 38.00mm | 147.0 CFM (4.12m³/min) | - | Ball | Tubeaxial | - | 48.0dB(A) | 9 W | 2900 RPM | 2 Wire Leads | - | -13 ~ 162°F (-25 ~ 72°C) | CE | 1.4 lbs (635.0 g) |
|
9WV1248P1J001FAN AXIAL 120X38MM 48VDC WIRE |
109 |
|
Datasheet | San Ace 120W | Box | Active | 48VDC | Square - 120mm L x 120mm H | 38.00mm | 224.0 CFM (6.27m³/min) | 1.450 in H2O (361.2 Pa) | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | 64.0dB(A) | 31.2 W | 6400 RPM | 4 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.97 lb (439.98 g) |
|
QG030-148/12FAN BLOWER CF 201X47.5MM 12VDC |
1,435 |
|
Datasheet | QG030 | Box | Active | 12VDC | Rectangular - 201mm L x 50mm H | 47.50mm | 44.0 CFM (1.23m³/min) | - | Ball | Blower, Cross Flow | - | 49.0dB(A) | 6.2 W | - | 2 Wire Leads | - | - | CE, CSA, UL, VDE | 0.56 lb (254.01 g) |
|
9SG5724P5H61FAN AXIAL 172X51MM 24VDC WIRE |
1,334 |
|
Datasheet | San Ace 172 | Box | Active | 24VDC | Rectangular/Rounded - 172mm L x 150mm H | 51.00mm | 410.0 CFM (11.48m³/min) | 2.160 in H2O (540.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, PWM Control, Speed Sensor (Tach) | 71.0dB(A) | 67.2 W | 6500 RPM | 4 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 0.882 lb (400.07 g) |
|
9LG1424A5001FAN AXIAL 140X51MM 24VDC WIRE |
1,301 |
|
Datasheet | San Ace 140L | Box | Active | 24VDC | Square - 140mm L x 140mm H | 51.00mm | 243.7 CFM (6.82m³/min) | 2.170 in H2O (540.5 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | - | 29.1 W | 5700 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | cURus, TUV | 1.8 lb (800.0 g) |
Frequently Asked Questions
What are DC Brushless Fans (BLDC) components used for?
DC Brushless Fans (BLDC) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right DC Brushless Fans (BLDC) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find DC Brushless Fans (BLDC) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.