| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Voltage - Rated | Size / Dimension | Width | Air Flow | Static Pressure | Bearing Type | Fan Type | Features | Noise | Power (Watts) | RPM | Termination | Ingress Protection | Operating Temperature | Approval Agency | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
9WS1248M102FAN AXIAL 119X38MM 48VDC WIRE |
2,020 |
|
Datasheet | San Ace 120WS | Box | Obsolete | 48VDC | Square - 119mm L x 119mm H | 38.00mm | 102.4 CFM (2.87m³/min) | 0.272 in H2O (67.7 Pa) | Ball | Tubeaxial | - | 39.0dB(A) | 5.52 W | 2600 RPM | 2 Wire Leads | IP54 - Dust Protected, Water Resistant | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 0.573 lb (259.91 g) |
|
|
109L0812S401FAN AXIAL 80X25MM 12VDC WIRE |
2,359 |
|
Datasheet | San Ace 80L | Box | Obsolete | 12VDC | Square - 80mm L x 80mm H | 25.00mm | 42.4 CFM (1.19m³/min) | 0.200 in H2O (49.8 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 37.0dB(A) | 3.12 W | 3400 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.331 lb (150.14 g) |
|
|
109L0824H401FAN AXIAL 80X25MM 24VDC WIRE |
4,739 |
|
Datasheet | San Ace 80L | Box | Obsolete | 24VDC | Square - 80mm L x 80mm H | 25.00mm | 37.4 CFM (1.05m³/min) | 0.157 in H2O (39.2 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 32.0dB(A) | 2.16 W | 3000 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.331 lb (150.14 g) |
|
|
109L0824H402FAN AXIAL 80X25MM 24VDC WIRE |
3,616 |
|
Datasheet | San Ace 80L | Box | Obsolete | 24VDC | Square - 80mm L x 80mm H | 25.00mm | 37.4 CFM (1.05m³/min) | 0.157 in H2O (39.2 Pa) | Ball | Tubeaxial | - | 32.0dB(A) | 2.16 W | 3000 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.331 lb (150.14 g) |
|
|
109L0824S401FAN AXIAL 80X25MM 24VDC WIRE |
2,863 |
|
Datasheet | San Ace 80L | Box | Obsolete | 24VDC | Square - 80mm L x 80mm H | 25.00mm | 42.4 CFM (1.19m³/min) | 0.200 in H2O (49.8 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 37.0dB(A) | 2.64 W | 3400 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.331 lb (150.14 g) |
|
|
109L0912H401FAN AXIAL 92X25MM 12VDC WIRE |
2,470 |
|
Datasheet | San Ace 92L | Box | Obsolete | 12VDC | Square - 92mm L x 92mm H | 25.00mm | 48.7 CFM (1.36m³/min) | 0.181 in H2O (45.1 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 33.0dB(A) | 2.52 W | 2850 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.375 lb (170.1 g) |
|
|
109L0924H402FAN AXIAL 92X25MM 24VDC WIRE |
2,761 |
|
Datasheet | San Ace 92L | Box | Obsolete | 24VDC | Square - 92mm L x 92mm H | 25.00mm | 48.7 CFM (1.36m³/min) | 0.181 in H2O (45.1 Pa) | Ball | Tubeaxial | - | 33.0dB(A) | 2.88 W | 2850 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.375 lb (170.1 g) |
|
109L1424H101FAN AXIAL 140X38MM 24VDC WIRE |
1,397 |
|
Datasheet | San Ace 140L | Box | Obsolete | 24VDC | Square - 140mm L x 140mm H | 38.00mm | 159.0 CFM (4.45m³/min) | 0.394 in H2O (98.1 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 46.0dB(A) | 8.88 W | 2600 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.3 lbs (600.0 g) |
|
109P0524H702FAN AXIAL 52X15MM 24VDC WIRE |
1,700 |
|
Datasheet | San Ace 52 | Box | Obsolete | 24VDC | Square - 52mm L x 52mm H | 15.00mm | 9.0 CFM (0.252m³/min) | 0.128 in H2O (31.8 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 27.0dB(A) | 1.2 W | 4600 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.122 lb (55.34 g) |
|
109P0524M702FAN AXIAL 52X15MM 24VDC WIRE |
3,310 |
|
Datasheet | San Ace 52 | Box | Obsolete | 24VDC | Square - 52mm L x 52mm H | 15.00mm | 7.2 CFM (0.202m³/min) | 0.086 in H2O (21.5 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 22.0dB(A) | 960 mW | 3700 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.122 lb (55.34 g) |
|
|
109P0612B7D01FAN AXIAL 60X15MM 12VDC WIRE |
2,449 |
|
Datasheet | San Ace 60 | Box | Obsolete | 12VDC | Square - 60mm L x 60mm H | 15.00mm | 7.4 CFM (0.207m³/min) | 0.047 in H2O (11.8 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 21.0dB(A) | 600 mW | 2200 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.133 lb (60.33 g) |
|
|
109P0612H7D01FAN AXIAL 60X15MM 12VDC WIRE |
1,317 |
|
Datasheet | San Ace 60 | Box | Obsolete | 12VDC | Square - 60mm L x 60mm H | 15.00mm | 14.1 CFM (0.395m³/min) | 0.153 in H2O (38.2 Pa) | Ball | Tubeaxial | Locked Rotor Sensor | 32.0dB(A) | 1.08 W | 4100 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.133 lb (60.33 g) |
|
|
109P0624H702FAN AXIAL 60X15MM 24VDC WIRE |
2,236 |
|
Datasheet | San Ace 60 | Box | Obsolete | 24VDC | Square - 60mm L x 60mm H | 15.00mm | 14.1 CFM (0.395m³/min) | 0.153 in H2O (38.2 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 32.0dB(A) | 1.44 W | 4100 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.133 lb (60.33 g) |
|
|
109P0624M602FAN AXIAL 60X20MM 24VDC WIRE |
2,233 |
|
Datasheet | San Ace 60 | Box | Obsolete | 24VDC | Square - 60mm L x 60mm H | 20.00mm | 10.6 CFM (0.297m³/min) | 0.076 in H2O (18.9 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 25.0dB(A) | 1.2 W | 3200 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.199 lb (90.26 g) |
|
|
109P0812A201FAN AXIAL 80X32MM 12VDC WIRE |
3,455 |
|
Datasheet | San Ace 80 | Box | Obsolete | 12VDC | Square - 80mm L x 80mm H | 32.00mm | 53.7 CFM (1.50m³/min) | 0.366 in H2O (91.2 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 45.0dB(A) | 6.72 W | 4600 RPM | 3 Wire Leads | - | -4 ~ 131°F (-20 ~ 55°C) | CSA, TUV, UL | 0.331 lb (150.14 g) |
|
|
109P0812H2011FAN AXIAL 80X32MM 12VDC WIRE |
1,578 |
|
Datasheet | San Ace 80 | Box | Obsolete | 12VDC | Square - 80mm L x 80mm H | 32.00mm | 37.1 CFM (1.04m³/min) | 0.173 in H2O (43.1 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 33.0dB(A) | 1.92 W | 3150 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.331 lb (150.14 g) |
|
109P0812M701FAN AXIAL 80X15MM 12VDC WIRE |
4,523 |
|
Datasheet | San Ace 80 | Box | Obsolete | 12VDC | Square - 80mm L x 80mm H | 15.00mm | 20.1 CFM (0.563m³/min) | 0.051 in H2O (12.7 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 21.0dB(A) | 1.08 W | 2000 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.15 lb (68.04 g) |
|
109P0812M702FAN AXIAL 80X15MM 12VDC WIRE |
4,884 |
|
Datasheet | San Ace 80 | Box | Obsolete | 12VDC | Square - 80mm L x 80mm H | 15.00mm | 20.1 CFM (0.563m³/min) | 0.051 in H2O (12.7 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 21.0dB(A) | 1.08 W | 2000 RPM | 2 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.15 lb (68.04 g) |
|
109P0812T6H12FAN AXIAL 80X20MM 12VDC WIRE |
1,851 |
|
Datasheet | San Ace 80 | Box | Obsolete | 12VDC | Square - 80mm L x 80mm H | 20.00mm | 29.7 CFM (0.832m³/min) | 0.118 in H2O (29.4 Pa) | Ball | Tubeaxial | Thermistor, External | 31.0dB(A) | 2.16 W | 2900 RPM | 3 Wire Leads | - | 14 ~ 140°F (-10 ~ 60°C) | CSA, TUV, UR | 0.222 lb (100.7 g) |
|
|
109P0824A201FAN AXIAL 80X32MM 24VDC WIRE |
1,604 |
|
Datasheet | San Ace 80 | Box | Obsolete | 24VDC | Square - 80mm L x 80mm H | 32.00mm | 53.7 CFM (1.50m³/min) | 0.366 in H2O (91.2 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 45.0dB(A) | 6.96 W | 4600 RPM | 3 Wire Leads | - | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 0.331 lb (150.14 g) |
Frequently Asked Questions
What are DC Brushless Fans (BLDC) components used for?
DC Brushless Fans (BLDC) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right DC Brushless Fans (BLDC) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find DC Brushless Fans (BLDC) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.