| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Voltage - Rated | Size / Dimension | Width | Air Flow | Static Pressure | Bearing Type | Fan Type | Features | Noise | Power (Watts) | RPM | Termination | Ingress Protection | Operating Temperature | Approval Agency | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
R3G190-RD45-03190 MM EC CENTRIFUGAL FAN |
565 |
|
Datasheet | Green Tech RadiCal® R3G190RD | Bulk | Active | 230VAC | Round - 190mm Dia | 90.70mm | 573.9 CFM (16.07m³/min) | - | Ball | Motorized Impellers | Electronic Commutation (EC) | 72.0dB(A) | 169W | 4120 RPM | 2 Wire Leads | IP54 - Dust Protected, Water Resistant | -13 ~ 140°F (-25 ~ 60°C) | UL | 3 lbs (1.4 kg) |
|
W3G250-HH07-03FAN AXIAL 230V 280X80MM 1000CFM |
139 |
|
Datasheet | W3G250 | Bulk | Active | 230VAC | Square - 280mm L x 280mm H | 80.00mm | 1000.0 CFM (28.00m³/min) | - | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | - | 83.0W | 2330 RPM | Terminal Block | IP54 - Dust Protected, Water Resistant | -13 ~ 140°F (-25 ~ 60°C) | CCC, CE, CSA | 4.6 lbs (2.1 kg) |
|
G4E180-AB09-15FAN BLWR CENT 261X125MM 115VAC |
1,904 |
|
Datasheet | G4E180 | Box | Active | 115VAC | Rectangular - 261mm L x 281mm H (180mm Dia) | 125.0mm | 350.0 CFM (9.80m³/min) | - | Ball | Blower, Centrifugal | - | 65.0dB(A) | 146W | - | 2 Wire Leads | - | - | - | 8.2 lbs (3.7 kg) |
|
D4E180-CA02-36BLOWER |
4,023 |
|
Datasheet | D4E180 | Bulk | Active | 230VAC | Rectangular/Rounded - 295mm L x 332mm H | 309.0mm | - | - | Ball | Blower, Centrifugal | Capacitor, Thermal Overload Protector (TOP) | - | 495W | 1300 RPM | 6 Wire Leads | IP44 | -13 ~ 95°F (-25 ~ 35°C) | CCC, CSA, UL | - |
|
4840NFAN AXIAL 119X38MM 115VAC TERM |
2,968 |
|
Datasheet | 4000N | Bulk | Active | 115VAC | Square - 119mm L x 119mm H | 38.00mm | 50.0 CFM (1.40m³/min) | - | Sintec | Tubeaxial | - | 26.0dB(A) | 10.00W | 1650 RPM | 2 Terminals | - | 14 ~ 167°F (-10 ~ 75°C) | CE, CSA, UL, VDE | 1.2 lbs (544.3 g) |
|
55416.25170FAN BLOWER CF 180X108MM 115VAC |
224 |
|
Datasheet | QLN65 | Bulk | Active | 115VAC | Rectangular - 266mm L x 90mm H (65mm Dia) | 108.0mm | 114.0 CFM (3.19m³/min) | 0.373 in H2O (93.0 Pa) | Sleeve | Blower, Cross Flow | - | - | 49.00W | 1700 RPM | Terminal Block | - | 32 ~ 140°F (0 ~ 60°C) | - | 2.7 lbs (1.2 kg) |
|
4850ZFAN AXIAL 119X38MM 230VAC TERM |
3,802 |
|
Datasheet | 4000Z | Bulk | Active | 230VAC | Square - 119mm L x 119mm H | 38.00mm | 58.8 CFM (1.64m³/min) | - | Sintec | Tubeaxial | - | 26.0dB(A) | 13.00W | 1700 RPM | 2 Terminals | - | 14 ~ 149°F (-10 ~ 65°C) | CE, CSA, UL, VDE | 1.2 lbs (544.3 g) |
|
|
3556FAN AXIAL 92X38MM 230VAC WIRE |
3,477 |
|
Datasheet | 3000 | Bulk | Active | 230VAC | Square - 92mm L x 92mm H | 38.00mm | 39.4 CFM (1.10m³/min) | - | Ball | Tubeaxial | - | 33.0dB(A) | 9.00W | 2400 RPM | 2 Wire Leads | - | -40 ~ 194°F (-40 ~ 90°C) | CE, CSA, UL, VDE | 0.926 lb (420.03 g) |
|
AC8300HFAN 85-265VAC 47CFM 8.3W 80X32MM |
443 |
|
Datasheet | AC8300H | Box | Active | 115VAC | Square - 80mm L x 80mm H | 32.00mm | 46.9 CFM (1.31m³/min) | - | Ball | Tubeaxial | - | 48.0dB(A) | 8.30W | 5000 RPM | 2 Wire Leads | IP54 - Dust Protected, Water Resistant | -4 ~ 167°F (-20 ~ 75°C) | CCC, CE, CSA, UL, VDE | 0.717 lb (325.22 g) |
|
R2S133-AE77-22MOTORIZED IMPELLER |
4,666 |
|
Datasheet | R2S133 | Bulk | Active | 115VAC | Round - 133.4mm Dia | 91.00mm | - | - | Ball | Motorized Impellers | Thermal Overload Protector (TOP) | - | 34.00W | 3150 RPM | 2 Wire Leads with Splice Terminals | IP22 | -13 ~ 113°F (-25 ~ 45°C) | CE, CSA, UL | - |
Frequently Asked Questions
What are AC Fans components used for?
AC Fans components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right AC Fans part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find AC Fans parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.