| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Voltage - Rated | Size / Dimension | Width | Air Flow | Static Pressure | Bearing Type | Fan Type | Features | Noise | Power (Watts) | RPM | Termination | Ingress Protection | Operating Temperature | Approval Agency | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
W2D250-HH14-10AC AXIAL FAN |
3,612 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
S4E350-BA06-02AC AXIAL FAN |
1,691 |
|
Datasheet | S4E350 | Bulk | Active | 230VAC | Round - 422mm Dia | - | 1878.9 CFM (52.61m³/min) | 0.361 in H2O (89.9 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protection (TOP) | 70.0dB(A) | 205W | 1550 RPM | 4 Wire Leads | IP44 | 86°F (30°C) | CE, UL | - |
|
EE1G-230-160-02AC CENTRIFUGAL BLOWER |
4,618 |
|
Datasheet | EE1G | Bulk | Active | 230VAC | - | - | - | - | Ball | Blower, Centrifugal | - | - | - | - | - | - | - | CSA, VDE, UL | - |
|
W2D250-HI02-05AC AXIAL FAN |
1,020 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
S4E360-EI07-55AC AXIAL FAN |
2,247 |
|
Datasheet | S4E360 | Bulk | Active | 230VAC | Round - 360mm Dia | - | - | - | Ball | Tubeaxial | - | - | - | - | - | - | - | CSA, VDE, UL | - |
|
S4E450-AP01-01FAN AXIAL |
3,174 |
|
Datasheet | S4E450 | Bulk | Active | 230VAC | Round - 477.2mm Dia | 164.8mm | 2173.4 CFM (60.86m³/min) | 0.141 in H2O (35.0 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | - | 355W | 1600 RPM | 4 Wire Leads with Splice Terminals | IP44 | -13 ~ 104°F (-25 ~ 40°C) | CE | - |
|
S4E450-AP01-02FAN AXIAL |
4,130 |
|
Datasheet | S4E450 | Bulk | Active | 230VAC | Round - 522mm Dia | 164.0mm | 2173.4 CFM (60.86m³/min) | 0.141 in H2O (35.0 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | - | 355W | 1600 RPM | 4 Wire Leads with Splice Terminals | IP44 | -13 ~ 104°F (-25 ~ 40°C) | CE, EAC | - |
|
A4D350-AA04-01AC AXIAL FAN |
2,129 |
|
Datasheet | A4D350 | Bulk | Active | 255/440VAC | Round - 353mm Dia | 101.5mm | 1054.3 CFM (29.52m³/min) | 0.482 in H2O (120.0 Pa) | Ball | Tubeaxial, 3 Phase | Dual Voltage | - | 200W | 1600 RPM | 7 Wire Leads | IP44 | -13 ~ 104°F (-25 ~ 40°C) | CE, EAC | - |
|
D2E146-CS03-01AC CENTRIFUGAL BLOWER |
1,253 |
|
Datasheet | D2E146 | Bulk | Active | - | Rectangular/Rounded - 220mm L x 216mm H | 195.0mm | - | - | Ball | Blower, Centrifugal | - | - | - | - | Terminal Block | - | - | CE, VDE | - |
|
K3G220-CD17-01EC CENTRIFUGAL BLOWER |
2,881 |
|
Datasheet | K3G220 | Bulk | Active | 230VAC | Square - 243mm L x 243mm H | 116.0mm | - | - | Ball | Tubeaxial | PWM Control, Speed Sensor (Tach) | - | 105W | 2670 RPM | 3 Wire Leads, 4 Wire Leads | IP44 | -13 ~ 140°F (-25 ~ 60°C) | CE | - |
|
|
R2E250-RC08-14CENTRIFUGAL FAN |
1,647 |
|
Datasheet | R2E250 | Bulk | Active | 230VAC | Round - 250mm Dia | 104.8mm | 356.3 CFM (9.98m³/min) | 1.630 in H2O (405.0 Pa) | Ball | Motorized Impellers | Capacitor, Thermal Overload Protector (TOP) | - | 340W | 2850 RPM | 4 Wire Leads with Splice Terminals | IP44 | -13 ~ 113°F (-25 ~ 45°C) | CE, CSA, UL | - |
|
W6E450-CP02-01FAN AXIAL |
2,591 |
|
Datasheet | W6E450 | Bulk | Active | 230VAC | Round - 607mm Dia | 164.0mm | - | 0.180 in H2O (44.8 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | - | 225W | 1070 RPM | 4 Wire Leads with Splice Terminals | IP44 | -13 ~ 140°F (-25 ~ 60°C) | EAC | - |
|
EE1G-230-180-04BLOWER |
3,014 |
|
Datasheet | EE1G180 | Bulk | Active | 230VAC | Rectangular/Rounded - 260mm L x 302mm H | 170.0mm | 450.0 CFM (12.60m³/min) | - | Ball | Blower, Centrifugal | Capacitor | 64.0dB(A) | 180W | - | 3 Wire Leads | - | 140°F (60°C) | - | - |
|
R4E355-AK13-07AC BACKWARD-CURVED MOTORIZED IMP |
2,298 |
|
Datasheet | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
R2E180-AH05-34MOTORIZED IMPELLER |
1,451 |
|
Datasheet | R2E180 | Bulk | Active | - | - | - | - | - | Ball | Motorized Impellers | Capacitor | - | - | - | - | - | - | - | - |
|
FC040-4/202956FAN AXIAL 540X188MM 230VAC WIRE |
3,358 |
|
Datasheet | FC040 | - | Obsolete | 230VAC | Square - 540mm L x 540mm H | 188.0mm | 3830.0 CFM (107.24m³/min) | - | Ball | Tubeaxial | - | 75.0dB(A) | 370W | - | 2 Wire Leads | - | - | - | 20 lbs (9.1 kg) |
|
A2E200-AF02-19AC AXIAL FAN |
3,438 |
|
Datasheet | A2E200 | Bulk | Active | 240VAC | Round - 195mm Dia | 68.00mm | - | 0.401 in H2O (100.0 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protection (TOP) | - | 76W | 3050 RPM | 4 Wire Leads | IP44 | -13 ~ 203°F (-25 ~ 95°C) | CE | - |
|
W4E350-DP18-72AC AXIAL FAN |
2,118 |
|
Datasheet | W4E350 | Bulk | Active | 115VAC | Square - 485mm L x 485mm H | 135.0mm | - | 0.241 in H2O (60.0 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protection (TOP) | - | 200W | 1590 RPM | 4 Wire Leads | IP44 | 122°F (50°C) | CSA, CE, UL | - |
|
W2D250-GA02-07FAN AXIAL |
3,275 |
|
Datasheet | W2D250 | Bulk | Active | 400VAC | Square - 268mm L x 268mm H | 82.50mm | 618.5 CFM (17.32m³/min) | 1.120 in H2O (280.0 Pa) | Ball | Tubeaxial, 3 Phase | - | - | 180W | 3000 RPM | 3 Position Rectangular Connector | IP44 | -13 ~ 122°F (-25 ~ 50°C) | CE, EAC | - |
|
55462.19891HOT AIR FANS / BLOWERS |
1,021 |
|
Datasheet | 55462 | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Frequently Asked Questions
What are AC Fans components used for?
AC Fans components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right AC Fans part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find AC Fans parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.