| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Voltage - Rated | Size / Dimension | Width | Air Flow | Static Pressure | Bearing Type | Fan Type | Features | Noise | Power (Watts) | RPM | Termination | Ingress Protection | Operating Temperature | Approval Agency | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A4E350-AR06-02AC AXIAL FAN |
4,505 |
|
Datasheet | A4E350 | Bulk | Active | 230VAC | Round - 352mm Dia | 102.0mm | 1234.0 CFM (34.55m³/min) | 0.261 in H2O (65.0 Pa) | Ball | Motorized Impellers | Capacitor, Thermal Overload Protection (TOP) | - | 180W | 1530 RPM | 4 Wire Leads | IP44 | 122°F (50°C) | CCC, CE | - |
|
RG225-63/14/2TDMLOAC FLATPAK - RADIAL BLOWER |
1,370 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
S6E315-BP02-31AC AXIAL FAN |
4,336 |
|
Datasheet | S6E315 | Bulk | Active | 230 ~ 277VAC | Round - 375mm Dia | 117.0mm | - | 0.321 in H2O (80.0 Pa) | Ball | Tubeaxial | Capacitor, Dual Voltage, Thermal Overload Protection (TOP) | - | 93.0W | 1140 RPM | 4 Wire Leads | IP44 | -13 ~ 140°F (-25 ~ 60°C) | CCC, CE, UL | - |
|
R2E120-CD70-09MOTORIZED IMPELLER |
4,569 |
|
Datasheet | R2E120 | Bulk | Active | - | Round - 120mm Dia | - | - | - | Ball | Motorized Impellers | Capacitor, Thermal Overload Protector (TOP) | - | - | - | - | - | - | - | - |
|
A4E300-AP26-09AC AXIAL FAN |
4,837 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
G2E140-AE77-97AC CENTRIFUGAL BLOWER |
1,479 |
|
Datasheet | G2E140 | Bulk | Active | 230VAC | Rectangular/Rounded - 261.5mm L x 226.8mm H | 130.0mm | - | - | Ball | Blower, Centrifugal | Capacitor, Thermal Overload Protection (TOP) | - | 120W | 1500 RPM | 4 Wire Leads | IP44 | -13 ~ 95°F (-25 ~ 35°C) | CCC, CSA, CE, UL | - |
|
A4D250-AA36-02FAN AC AXIAL |
3,885 |
|
Datasheet | * | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
S2D200-BA04-17AC AXIAL FAN |
1,990 |
|
Datasheet | S2D200 | Bulk | Active | 500VAC | Round - 245mm Dia | 72.70mm | 430.0 CFM (12.04m³/min) | 0.330 in H2O (82.2 Pa) | Ball | Tubeaxial, 3 Phase | - | - | 70W | 3150 RPM | 4 Wire Leads | IP44 | -13 ~ 194°F (-25 ~ 90°C) | CE | - |
|
W2E200-CI38-73FAN AXIAL |
1,296 |
|
Datasheet | W2E200 | Bulk | Active | 230VAC | Round - 280mm Dia | 89.00mm | - | 0.602 in H2O (150.0 Pa) | Ball | Tubeaxial | Capacitor, Thermal Overload Protector (TOP) | - | 83.0W | 2900 RPM | 4 Wire Leads with Splice Terminals | IP44 | -13 ~ 149°F (-25 ~ 65°C) | CE, CSA, UL | - |
|
W2E208-BA86-01AC AXIAL FAN |
3,507 |
|
Datasheet | W2E208 | Bulk | Active | 115VAC | Round - 260mm Dia | 80.00mm | 544.8 CFM (15.26m³/min) | 0.662 in H2O (165.0 Pa) | Ball | Tubeaxial | - | 70.0dB(A) | 87.0W | 3100 RPM | 2 Terminals | IP44 | -13 ~ 162°F (-25 ~ 72°C) | CCC, GOST, VDE | - |
|
R2D220-AA24-13MOTORIZED IMPELLER |
4,650 |
|
Datasheet | R2D220 | Bulk | Obsolete | 230/400VAC | Round - 221.4mm Dia | 71.00mm | - | - | Ball | Motorized Impellers, 3 Phase | Thermal Overload Protector (TOP) | - | 82.0W | 2600 RPM | 9 Wire Leads with Splice Terminals | IP44 | -13 ~ 122°F (-25 ~ 50°C) | CE | - |
|
W2D208-BA02-01AC AXIAL FAN |
3,728 |
|
Datasheet | W2D208 | Bulk | Active | 400VAC | Round - 260mm Dia | 80.00mm | 541.9 CFM (15.17m³/min) | 0.682 in H2O (170.0 Pa) | Ball | Tubeaxial, 3 Phase | - | 70.0dB(A) | 80W | 3090 RPM | Terminal Block | IP44 | 158°F (70°C) | CCC, GOST, VDE | - |
|
W4S250-CH02-01AC AXIAL FAN |
3,693 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
W4S250-CI02-01AC AXIAL FAN |
2,280 |
|
Datasheet | W4S250 | Bulk | Active | 230VAC | Round - 320mm Dia | 96.00mm | 683.2 CFM (19.13m³/min) | 0.321 in H2O (80.0 Pa) | Ball | Tubeaxial | Thermal Overload Protection (TOP) | 58.0dB(A) | 63.0W | 1600 RPM | 3 Wire Leads | IP44 | 149°F (65°C) | CCC | - |
|
W2E250-DB13-51AC AXIAL FAN |
3,321 |
|
Datasheet | W2E250 | Bulk | Active | 115VAC | Square - 370mm L x 370mm H | 83.00mm | - | - | Ball | Tubeaxial | Capacitor, Thermal Overload Protection (TOP) | - | 180W | 2650 RPM | 4 Wire Leads | IP44 | -13°F (-25°C) | CSA, CE, UL | - |
|
W2D250-CA02-52AC AXIAL FAN |
4,764 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
S2D250-BA02-02AC AXIAL FAN |
4,860 |
|
Datasheet | S2D250 | Bulk | Active | 400VAC | Round - 248mm Dia | 83.00mm | 618.5 CFM (17.32m³/min) | 1.200 in H2O (298.9 Pa) | Ball | Tubeaxial, 3 Phase | - | - | 160W | 2950 RPM | 7 Wire Leads | IP44 | -13 ~ 104°F (-25 ~ 40°C) | CCC, CE | - |
|
S2D250-BA02-01AC AXIAL FAN |
1,007 |
|
Datasheet | S2D250 | Bulk | Active | 230VAC/400VAC | Round - 290mm Dia | 87.00mm | 1086.7 CFM (30.43m³/min) | - | Ball | Tubeaxial, 3 Phase | Dual Voltage | 75.0dB(A) | 160W | 2950 RPM | 2 Wire Leads | IP44 | 104°F (40°C) | - | - |
|
R2E250-AL03-10AC BACKWARD-CURVED MOTORIZED IMP |
1,456 |
|
Datasheet | R2E250 | Bulk | Active | 230VAC | Round - 252mm Dia | 120.5mm | - | - | Ball | Motorized Impellers | Capacitor, Thermal Overload Protection (TOP) | - | 315W | 3000 RPM | 3 Wire Leads | - | -13 ~ 95°F (-25 ~ 35°C) | UL | - |
|
EE1G-115-140-04AC CENTRIFUGAL BLOWER |
3,259 |
|
Datasheet | EE1G | Bulk | Active | 115VAC | Rectangular/Rounded - 256.54mm L x 220mm H | 130.0mm | 270.0 CFM (7.56m³/min) | - | Ball | Blower, Centrifugal | - | 64.0dB(A) | 195W | - | 2 Wire Leads | - | 122°F (50°C) | CSA, VDE, UL | - |
Frequently Asked Questions
What are AC Fans components used for?
AC Fans components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right AC Fans part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find AC Fans parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.