| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Range | Output Type | Control Method | Communications | Number of Characters Per Row | Display Type | Display Characters - Height | Voltage - Supply | Panel Cutout Dimensions | Mounting Type | Termination Style | Ingress Protection | Features |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
THYRO-A+ 2A 500-130 H RL 4THYRO-A+ 2A 500-130 H RL 4 |
1,176 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 130A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | Chassis Mount | Screw Terminal | - | Heater Fault Detection |
|
E5AR-PR4F-DRT AC100-240VCONTROL TEMP/PROCESS 100-240V |
1,579 |
|
Datasheet | E5AR | Bulk | Obsolete | Process, Temperature Controller (RTD, Type B, E, J, K, L, N, R, S, T, U, W) | -200°C ~ 2300°C, 0 ~ 20mA, 0 ~ 10VDC | Relay (6) | On/Off, Proportional (PID) | DeviceNet | 5, 5, 4 | LCD - Tri Color Characters, Backlight | 0.504" (12.80mm), 0.303" (7.70mm), 0.303" (7.70mm) | 100 ~ 240VAC | Square - 92.00mm x 92.00mm | Panel Mount | Screw Terminal | IP66 - Dust Tight, Water Resistant | - |
|
E5AR-PR4F-DRT AC24VCONTROL TEMP/PROC RELAY OUT 24V |
3,369 |
|
Datasheet | E5AR | Bulk | Obsolete | Process, Temperature Controller (RTD, Type B, E, J, K, L, N, R, S, T, U, W) | -200°C ~ 2300°C, 0 ~ 20mA, 0 ~ 10VDC | Relay (6) | On/Off, Proportional (PID) | DeviceNet | 5, 5, 4 | LCD - Tri Color Characters, Backlight | 0.504" (12.80mm), 0.303" (7.70mm), 0.303" (7.70mm) | 24VAC/DC | Square - 92.00mm x 92.00mm | Panel Mount | Screw Terminal | IP66 - Dust Tight, Water Resistant | - |
|
THYRO-A 3A 500-60 H3THYRO-A 3A 500-60 H3 |
3,107 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 60A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 3A 500-8 HRLP3THYRO-A 3A 500-8 HRLP3 |
4,429 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 3A 500-16 HRLP3THYRO-A 3A 500-16 HRLP3 |
3,825 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 16A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-PX 1PX 500-130 HTHYRO-PX 1PX 500-130 H |
4,839 |
|
Datasheet | Thyro-PX® | Box | Active | Power Controller | 16 ~ 130A, 184 ~ 550VAC | Analog (3) | On/Off, Phase Control | USB | - | - | - | 90 ~ 265VAC, 21.6 ~ 26.4VDC | - | Chassis Mount | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 1A 400-350 HFRL3THYRO-A 1A 400-350 HFRL3 |
3,719 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 350A, 172 ~ 440VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 3A 400-60 HRL3THYRO-A 3A 400-60 HRL3 |
3,080 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 60A, 172 ~ 440VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 2A 400-100 HRLP3THYRO-A 2A 400-100 HRLP3 |
3,241 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 100A, 172 ~ 440VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A+ 1A 230-350 HF RL 4THYRO-A+ 1A 230-350 HF RL 4 |
1,969 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 350A, 99 ~ 253VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | Chassis Mount | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 1A 400-45 H RLP3 C05THYRO-A 1A 400-45 H RLP3 C05 |
3,121 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 45A, 172 ~ 440VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
E5ER-QTB-DRT AC24VCONTROL TEMP/PROCESS SS/VOLT OUT |
4,699 |
|
Datasheet | E5ER | Box | Obsolete | Process, Temperature Controller (RTD, Type B, E, J, K, L, N, R, S, T, U, W) | -200°C ~ 2300°C, 0 ~ 20mA, 0 ~ 10VDC | Solid State (2), Voltage (External SSR) (2) | On/Off, Proportional (PID) | DeviceNet | 5, 5, 3 | LCD - Tri Color Characters, Backlight | 0.374" (9.50mm), 0.283" (7.20mm), 0.283" (7.20mm) | 24VAC | Rectangular - 92.00mm x 45.00mm | Panel Mount | Screw Terminal | IP66 - Dust Tight, Water Resistant | Event Input |
|
THYRO-A+ 1A 500-280 HF RL 4THYRO-A+ 1A 500-280 HF RL 4 |
1,130 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 280A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | Chassis Mount | Screw Terminal | - | Heater Fault Detection |
|
THYRO-S 3S 500-130 H3THYRO-S 3S 500-130 H3 |
2,557 |
|
Datasheet | Thyro-S® | Box | Active | Power Controller | 8 ~ 130A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 3A 400-100 H3THYRO-A 3A 400-100 H3 |
4,392 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 100A, 172 ~ 440VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 1A 400-280 HFRLP3THYRO-A 1A 400-280 HFRLP3 |
1,292 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 280A, 172 ~ 440VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A+ 1A 230-280 HF RLP 4THYRO-A+ 1A 230-280 HF RLP 4 |
4,286 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 280A, 99 ~ 253VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | Chassis Mount | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 1A 500-280 HFRL3THYRO-A 1A 500-280 HFRL3 |
4,551 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 280A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
|
THYRO-A 2A 500-170 H3THYRO-A 2A 500-170 H3 |
4,900 |
|
Datasheet | Thyro-A® | Box | Active | Power Controller | 8 ~ 170A, 215 ~ 550VAC | Analog, Relay | On/Off, Phase Control | USB | - | - | - | 18 ~ 32VAC/DC | - | DIN Rail | Screw Terminal | - | Heater Fault Detection |
Frequently Asked Questions
What are Process, Temperature components used for?
Process, Temperature components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Process, Temperature part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Process, Temperature parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.