Machine Safety
Explore Machine Safety parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to ICMENU. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Controller Type | Number of Inputs and Type | Safety Outputs and Type | Auxiliary Outputs and Type | Contact Rating @ Voltage | Safety Category | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature | Ingress Protection | Features |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
1085351SAFETY CONTROLLERS, FLEXI COMPAC |
3,236 |
|
Datasheet | Flexi Compact | Bulk | Active | General Purpose | 20 - Digital | 12 - Digital | - | - | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Spring Terminal | -25°C ~ 55°C | IP20 | - |
|
6029947SAFETY INTERLOOK |
3,128 |
|
Datasheet | T4000 Multi | Bulk | Active | General Purpose | 4 - Digital | Relay (2) | - | 6A @ 30VDC | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Spring Terminal | 0°C ~ 55°C | IP20 | - |
|
NX-SL5500SAFETY CPU CIP 127 CONN 2MB |
4,453 |
|
Datasheet | NX | Bulk | Active | General Purpose | - | - | - | - | Category 4, PLe, SIL3 | - | DIN Rail | Spring Terminal | 0°C ~ 55°C | - | - |
|
XPSABV1133CMODULE XPSABV - STOP AND SWITCH |
1,890 |
|
Datasheet | Harmony XPS | Box | Obsolete | General Purpose | - | Relay (3) | - | - | Category 4 | 24VAC/DC | DIN Rail | Screw Terminal | -25°C ~ 55°C | IP20 | - |
|
XPSTSA3442PMODULE XPSTS - INTERLOCKING ON H |
3,066 |
|
Datasheet | Preventa XPS | Box | Obsolete | General Purpose | - | Relay (3), Solid State (2) | - | - | Category 3 | 115VAC | DIN Rail | Screw Terminal | -10°C ~ 55°C | IP20 | - |
|
XPSABV11330CMODULE XPSABV - STOP AND SWITCH |
4,661 |
|
Datasheet | Harmony XPS | Box | Obsolete | General Purpose | - | Relay (2) | - | - | Category 4 | 24VAC/DC | DIN Rail | Screw Terminal | -25°C ~ 55°C | IP20 | - |
|
XPSTSW5142PMODULE XPSTS - SAFETY SWITCHOVER |
1,106 |
|
Datasheet | Preventa XPS | Box | Obsolete | General Purpose | - | Relay (3), Solid State (3) | - | - | Category 3 | 24VAC/DC | DIN Rail | Screw Terminal | -10°C ~ 55°C | IP20 | - |
|
XPSTSW3442PMODULE XPSTS - SAFETY SWITCHOVER |
2,547 |
|
Datasheet | Preventa XPS | Box | Obsolete | General Purpose | - | Relay (3), Solid State (2) | - | - | Category 3 | 115VAC | DIN Rail | Screw Terminal | -10°C ~ 55°C | IP20 | - |
|
|
2986229CONTROL SAFETY GEN PURPOSE 24V |
4,864 |
|
Datasheet | PSR | Bulk | Obsolete | General Purpose | 20 - Digital | Solid State (4) | - | - | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Screw Terminal | -20°C ~ 55°C | IP54 - Dust Protected, Water Resistant | Grounded Switching Output, Test Output |
|
SFC-R212-LSAFETY CONT RELAY UNIT 24V |
4,651 |
|
Datasheet | SFC-R | Tape & Box (TB) | Active | General Purpose | 5 - Digital | Relay (2) | Solid State | 5A @ 240VAC/30VDC | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Spring Terminal | -10°C ~ 55°C | IP20 | - |
|
SFC-R212SAFETY CONT RELAY UNIT 24V |
4,805 |
|
Datasheet | SFC-R | Tape & Box (TB) | Active | General Purpose | 5 - Digital | Relay (2) | Solid State | 5A @ 240VAC/30VDC | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Screw Terminal | -10°C ~ 55°C | IP20 | - |
|
SFC-R412SAFETY CONT 4 RELAY UNIT 24V |
1,660 |
|
Datasheet | SFC-R | Tape & Box (TB) | Active | General Purpose | 5 - Digital | Relay (4) | Solid State | 5A @ 240VAC/30VDC | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Screw Terminal | -10°C ~ 55°C | IP20 | - |
|
SFC-422SAFETY CONTROL 2PR PNP OUT 24V |
1,749 |
|
Datasheet | SFC | Tape & Box (TB) | Active | General Purpose | 20 - Digital | Relay (4) | Solid State (2) | - | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Screw Terminal | -10°C ~ 55°C | IP20 | - |
|
SFC-ER412-LRELAY OUTPUT EXPENSION 24V |
4,421 |
|
Datasheet | SFC-ER | Tape & Box (TB) | Active | Expansion Module | 5 - Digital | Relay (4) | Solid State | 5A @ 240VAC/30VDC | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Spring Terminal | -10°C ~ 55°C | IP20 | - |
|
SFC-R212-R23SAFETY CONT RELAY UNIT 3SEC 24V |
4,885 |
|
Datasheet | SFC-R | Tape & Box (TB) | Active | General Purpose | 5 - Digital | Relay (4) | Solid State | 5A @ 240VAC/30VDC | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Screw Terminal | -10°C ~ 55°C | IP20 | Delay Time 0 ~ 3sec |
|
SFC-R212-R230-LSAFETY CONT RELAY UNIT 30S 24V |
1,462 |
|
Datasheet | SFC-R | Tape & Box (TB) | Active | General Purpose | 5 - Digital | Relay (4) | Solid State | 5A @ 240VAC/30VDC | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Spring Terminal | -10°C ~ 55°C | IP20 | Delay Time 0 ~ 30sec |
|
SFC-A322-2300-LSAFETY CONT OFF-DELAY 300S 24V |
4,937 |
|
Datasheet | SFC-A | Tape & Box (TB) | Active | General Purpose | 20 - Digital | Relay (5) | Solid State (2) | - | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Spring Terminal | -10°C ~ 55°C | IP20 | Delay Time 0 ~ 300sec |
|
SFC-N322-23SAFETY CONT OFF-DELAY 3SEC 24V |
2,566 |
|
Datasheet | SFC-N | Tape & Box (TB) | Active | General Purpose | 20 - Digital | Relay (5) | Solid State (2) | - | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Screw Terminal | -10°C ~ 55°C | IP20 | Delay Time 0 ~ 3sec |
|
SFC-N322-2300-LSAFETY CONT OFF-DELAY 300S 24V |
1,153 |
|
Datasheet | SFC-N | Tape & Box (TB) | Active | General Purpose | 20 - Digital | Relay (5) | Solid State (2) | - | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Spring Terminal | -10°C ~ 55°C | IP20 | Delay Time 0 ~ 300sec |
|
SFC-N322-2300SAFETY CONT OFF-DELAY 300S 24V |
1,049 |
|
Datasheet | SFC-N | Tape & Box (TB) | Active | General Purpose | 20 - Digital | Relay (5) | Solid State (2) | - | Category 4, PLe, SIL3 | 24VDC | DIN Rail | Screw Terminal | -10°C ~ 55°C | IP20 | Delay Time 0 ~ 300sec |
Frequently Asked Questions
What are Machine Safety components used for?
Machine Safety components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Machine Safety part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Machine Safety parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.