| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Voltage - Supply | Sensitivity | Features | Distance - Control To Sensor (Max) | Output Type | Contact Form | Contact Rating @ Voltage | Mounting Type | Termination Style | Operating Temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
61F-GP-NH AC100CNTRL LIQ LEV 100VAC SOCKETABLE |
3,535 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 100VAC | 10kOhm ~ 40kOhm | - | 50m | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-NL 2KM AC120CNTRL LIQ LEV 120VAC SOCKETABLE |
3,813 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 120VAC | 0 ~ 1.3kOhm | - | 2km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-NL 4KM AC120CNTRL LIQ LEV 120VAC SOCKETABLE |
3,463 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 120VAC | 0 ~ 0.5kOhm | - | 4km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-NL AC24 4KMCONTROL LIQ LEV 24VAC SOCKETABLE |
4,876 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 24VAC | 0 ~ 0.5kOhm | - | 4km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-NT AC110CNTRL LIQ LEV 110VAC SOCKETABLE |
4,992 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 110VAC | 0 ~ 4kOhm | - | 600m | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 8 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-NT AC120CNTRL LIQ LEV 120VAC SOCKETABLE |
1,332 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 120VAC | 0 ~ 4kOhm | - | 600m | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 8 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-ND AC200CNTRL LIQ LEV 200VAC SOCKETABLE |
2,683 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 200VAC | 0 ~ 1.3kOhm | - | 1km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-N AC100CNTRL LIQ LEV 100VAC SOCKETABLE |
4,419 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 100VAC | 0 ~ 4kOhm | Level Indication | 1km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-N AC110CNTRL LIQ LEV 110VAC SOCKETABLE |
1,047 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 110VAC | 0 ~ 4kOhm | Level Indication | 1km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-N-AC200CNTRL LIQ LEV 200VAC SOCKETABLE |
2,979 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 200VAC | 0 ~ 4kOhm | - | 1km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-N AC220CNTRL LIQ LEV 220VAC SOCKETABLE |
2,755 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 220VAC | 0 ~ 4kOhm | Level Indication | 1km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-ND AC120CNTRL LIQ LEV 120VAC SOCKETABLE |
3,836 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 120VAC | 0 ~ 1.3kOhm | - | 1km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-NR-AC100CNTRL LIQ LEV 100VAC SOCKETABLE |
1,918 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 100VAC | 0 ~ 2kOhm | Two Wire/Three Probe | 800m | Relay | SPST-NO (1 Form A), SPDT (1 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-N AC240CNTRL LIQ LEV 240VAC SOCKETABLE |
1,080 |
|
Datasheet | 61F | Box | Obsolete | High/Low Level | 240VAC | 0 ~ 4kOhm | Level Indication | 1km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-G1H AC120/240VCONTROL LIQ LEV 120/240VAC CHAS |
2,648 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 120/240VAC | 15kOhm ~ 70kOhm | Alarm Low - Contact, Idling Prevention | 50m | Relay (2) | SPDT (2 Form C) | 5A @ 220VAC | Chassis Mount | Screw Terminal | -10°C ~ 55°C |
|
61F-GP-N-AC120CNTRL LIQ LEV 120VAC SOCKETABLE |
1,000 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 120VAC | 0 ~ 4kOhm | - | 1km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-G3N AC120/240CNTRL LIQ LEV 120/240VAC DINRAIL |
4,058 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 120/240VAC | 0 ~ 4kOhm | Alarm High - Contact | 1km | Relay (3) | SPDT (2 Form C) | 3A @ 200VAC | DIN Rail | Screw Terminal | -10°C ~ 55°C |
|
61F-GP-ND-AC100CNTRL LIQ LEV 100VAC SOCKETABLE |
4,291 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 100VAC | 0 ~ 1.3kOhm | - | 1km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 11 Pin (Octal) | -10°C ~ 55°C |
|
61F-GP-N8Y 110VACCNTRL LIQ LEV 110VAC SOCKETABLE |
4,280 |
|
Datasheet | 61F | Bulk | Obsolete | High/Low Level | 110VAC | 0 ~ 4kOhm | - | 1km | Relay | SPDT (2 Form C) | 3A @ 250VAC | Socketable | Plug In, 8 Pin (Octal) | -10°C ~ 55°C |
|
H496166230LEVEL CONTROL RELAY |
3,527 |
|
Datasheet | H 496 | Box | Active | High/Low Level | 230VAC | 200Ohm ~ 220kOhm | Adjustable Sensitivity | - | Relay | DPDT (2 Form C) | 8A @ 250VAC | DIN Rail | Screw Terminal | -20°C ~ 50°C |
Frequently Asked Questions
What are Liquid, Level components used for?
Liquid, Level components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Liquid, Level part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can ICMENU help source obsolete or hard-to-find Liquid, Level parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.