ICMENU Electronics — Your one-stop global supplier of chips and electronic components.
FILTERED COMPONENT SELECTION

AC DC Converters

Review AC DC Converters Power Supplies - External/Internal (Off-Board) components in this filtered selection. Compare manufacturer information, availability, pricing, datasheets and key specifications to narrow down suitable parts for your application.

If the exact part or specification you need is not listed, send the manufacturer part number, target parameters and quantity to ICMENU for sourcing and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Number of Outputs Voltage - Input Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Output 5 Voltage - Output 6 Current - Output 1 Current - Output 2 Current - Output 3 Current - Output 4 Current - Output 5 Current - Output 6 Power (Watts) Applications Voltage - Isolation Operating Temperature Features Mounting Type Size / Dimension
UMP10T-S2D-S2D-S2E-S2E-S2L-ILL-A5-A ARTESYN / Advanced Energy

UMP10T-S2D-S2D-S2E-S2E-S2L-ILL-A5-A

AC/DC CNVT 2X3.3V 2X5V 12V 960W

ARTESYN / Advanced Energy

3,479
Datasheet µMP10 GEN II (1200W) Bulk Active Enclosed 7 85 ~ 264 VAC, 120 ~ 350 VDC 3.3V 3.3V 5V 5V 12V 12V 40 A 40 A 36 A 36 A 20 A 4 A 960W ITE (Commercial), Medical - -40°C ~ 70°C (With Derating) DC Input Capable, I2C Interface, PFC, PMBus™, Remote On/Off Chassis Mount 10.11" L x 5.00" W x 1.57" H (256.9mm x 127.0mm x 40.0mm)
UMP10T-S2D-S2E-S2E-S2L-S2Q-00-A ARTESYN / Advanced Energy

UMP10T-S2D-S2E-S2E-S2L-S2Q-00-A

ACDC CNVT 3.3V 2X5V 12V 24V 972W

ARTESYN / Advanced Energy

4,084
Datasheet µMP10 GEN II (1200W) Bulk Active Enclosed 5 85 ~ 264 VAC, 120 ~ 350 VDC 3.3V 5V 5V 12V 24V - 40 A 36 A 36 A 20 A 10 A - 972W ITE (Commercial), Medical - -40°C ~ 70°C (With Derating) DC Input Capable, I2C Interface, PFC, PMBus™, Remote On/Off Chassis Mount 10.11" L x 5.00" W x 1.57" H (256.9mm x 127.0mm x 40.0mm)
UMP10T-S2D-S2E-S2E-S2L-S2Q-20-A ARTESYN / Advanced Energy

UMP10T-S2D-S2E-S2E-S2L-S2Q-20-A

AC/DC CNVRT 3.3V 5V 12V 24V 972W

ARTESYN / Advanced Energy

4,982
Datasheet µMP10 GEN II (1200W) Bulk Active Enclosed 4 85 ~ 264 VAC, 120 ~ 350 VDC 3.3V 5V 12V 24V - - 40 A 72 A 20 A 10 A - - 972W ITE (Commercial), Medical - -40°C ~ 70°C (With Derating) DC Input Capable, I2C Interface, PFC, PMBus™, Remote On/Off Chassis Mount 10.11" L x 5.00" W x 1.57" H (256.9mm x 127.0mm x 40.0mm)
UMP10T-S2D-S2E-S2Q-S2Q-30-A ARTESYN / Advanced Energy

UMP10T-S2D-S2E-S2Q-S2Q-30-A

AC/DC CONVERTER 3.3V 5V 24V 792W

ARTESYN / Advanced Energy

3,659
Datasheet µMP10 GEN II (1200W) Bulk Active Enclosed 3 85 ~ 264 VAC, 120 ~ 350 VDC 3.3V 5V 24V - - - 40 A 36 A 20 A - - - 792W ITE (Commercial), Medical - -40°C ~ 70°C (With Derating) DC Input Capable, I2C Interface, PFC, PMBus™, Remote On/Off Chassis Mount 10.11" L x 5.00" W x 1.57" H (256.9mm x 127.0mm x 40.0mm)
UMP10T-S2D-S2E-S2Q-S2Q-S2Q-00-A ARTESYN / Advanced Energy

UMP10T-S2D-S2E-S2Q-S2Q-S2Q-00-A

AC/DC CNVT 3.3V 5V 3X24V 1032W

ARTESYN / Advanced Energy

2,349
Datasheet µMP10 GEN II (1200W) Bulk Active Enclosed 5 85 ~ 264 VAC, 120 ~ 350 VDC 3.3V 5V 24V 24V 24V - 40 A 36 A 10 A 10 A 10 A - 1032W ITE (Commercial), Medical - -40°C ~ 70°C (With Derating) DC Input Capable, I2C Interface, PFC, PMBus™, Remote On/Off Chassis Mount 10.11" L x 5.00" W x 1.57" H (256.9mm x 127.0mm x 40.0mm)
UMP10T-S2E-S2E-S2E-S2L-S2L-63-A ARTESYN / Advanced Energy

UMP10T-S2E-S2E-S2E-S2L-S2L-63-A

AC/DC CONVERTER 5V 2X12V 1020W

ARTESYN / Advanced Energy

3,769
Datasheet µMP10 GEN II (1200W) Bulk Active Enclosed 3 85 ~ 264 VAC, 120 ~ 350 VDC 5V 12V 12V - - - 108 A 20 A 20 A - - - 1020W ITE (Commercial), Medical - -40°C ~ 70°C (With Derating) DC Input Capable, I2C Interface, PFC, PMBus™, Remote On/Off Chassis Mount 10.11" L x 5.00" W x 1.57" H (256.9mm x 127.0mm x 40.0mm)
UMP10T-S2E-S2E-S2L-S2L-S2D-ILL-A0-A ARTESYN / Advanced Energy

UMP10T-S2E-S2E-S2L-S2L-S2D-ILL-A0-A

AC/DC CNVT 2X5V 2X12V 3.3V 1068W

ARTESYN / Advanced Energy

2,800
Datasheet µMP10 GEN II (1200W) Bulk Active Enclosed 7 85 ~ 264 VAC, 120 ~ 350 VDC 5V 5V 12V 12V 3.3V 12V 36 A 36 A 20 A 20 A 40 A 4 A 1068W ITE (Commercial), Medical - -40°C ~ 70°C (With Derating) DC Input Capable, I2C Interface, PFC, PMBus™, Remote On/Off Chassis Mount 10.11" L x 5.00" W x 1.57" H (256.9mm x 127.0mm x 40.0mm)
UMP10T-S2E-S2L-S2Q-S2Q-S2Q-40-A ARTESYN / Advanced Energy

UMP10T-S2E-S2L-S2Q-S2Q-S2Q-40-A

AC/DC CNVRTR 5V 12V 2X24V 1140W

ARTESYN / Advanced Energy

1,692
Datasheet µMP10 GEN II (1200W) Bulk Active Enclosed 4 85 ~ 264 VAC, 120 ~ 350 VDC 5V 12V 24V 24V - - 36 A 20 A 10 A 20 A - - 1140W ITE (Commercial), Medical - -40°C ~ 70°C (With Derating) DC Input Capable, I2C Interface, PFC, PMBus™, Remote On/Off Chassis Mount 10.11" L x 5.00" W x 1.57" H (256.9mm x 127.0mm x 40.0mm)
UMP10T-S2E-S2L-S2Q-S2Q-S2W-S2W-50-A ARTESYN / Advanced Energy

UMP10T-S2E-S2L-S2Q-S2Q-S2W-S2W-50-A

ACDC CNVT 5V 12V 2X24V 48V 1380W

ARTESYN / Advanced Energy

3,059
Datasheet µMP10 GEN II (1200W) Bulk Active Enclosed 6 85 ~ 264 VAC, 120 ~ 350 VDC 5V 12V 24V 24V 48V 48V 36 A 20 A 10 A 10 A 5 A 5 A 1380W ITE (Commercial), Medical - -40°C ~ 70°C (With Derating) DC Input Capable, I2C Interface, PFC, PMBus™, Remote On/Off Chassis Mount 10.11" L x 5.00" W x 1.57" H (256.9mm x 127.0mm x 40.0mm)
UMP10T-S2E-S2L-S2Q-S2W-S2W-S2W-00-B ARTESYN / Advanced Energy

UMP10T-S2E-S2L-S2Q-S2W-S2W-S2W-00-B

ACDC CNVT 5V 12V 24V 2X48V 1380W

ARTESYN / Advanced Energy

1,222
Datasheet µMP10 GEN II (1200W) Bulk Active Enclosed 6 85 ~ 264 VAC, 120 ~ 350 VDC 5V 12V 24V 48V 48V 48V 36 A 20 A 10 A 5 A 5 A 5 A 1380W ITE (Commercial), Medical - -40°C ~ 70°C (With Derating) DC Input Capable, I2C Interface, PFC, PMBus™, Remote On/Off Chassis Mount 10.11" L x 5.00" W x 1.57" H (256.9mm x 127.0mm x 40.0mm)
Total 5220 Record«Prev1... 496497498499500501502503...522Next»
FAQ

Frequently Asked Questions

What are AC DC Converters components used for?

AC DC Converters components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right AC DC Converters part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can ICMENU help source obsolete or hard-to-find AC DC Converters parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. ICMENU will review your request and provide available stock, pricing and sourcing information.

PART MATCHING & SOURCING

Need Help Narrowing Down the Right AC DC Converters Part?

Send your target specifications, preferred manufacturer, quantity or reference part number. Our team can help check matching options, availability and quotation details for your sourcing requirement.

BOM +00852-58089738 [email protected] Shopping Cart My Account Back To Top